Valor 530XAN/XAP Скачать руководство пользователя страница 4

44

Safety and Warning Information

Children and adults should be 

ALERTED

 to the 

hazards of high surface temperature and should 

STAY AWAY

 to avoid burns or clothing ignition. Young 

children should be 

CAREFULLY

 

SUPERVISED

 when 

they are in the same room as the appliance.

DO NOT 

place furniture or any other combustible 

household objects within 36” of the 

fi

 replace front.

READ

 and 

UNDERSTAND

 all instructions carefully 

before starting the installation. 

FAILURE TO FOLLOW

 

these installation instructions may result in possible 

fi

 re 

hazard and will void the warranty.

Prior to the 

fi

 rst 

fi

 ring of the 

fi

 replace, 

READ

 the 

Owner’s Information section of this manual.

DO NOT USE 

this appliance if any part has been under 

water. Immediately, 

CALL

 a quali

fi

 ed service technician 

to inspect the unit and to replace any part of the control 
system and any gas control that has been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED

 by a 

quali

fi

 ed service person. The appliance and venting 

system should be 

INSPECTED

 before initial use and at 

least annually by a professional service person. More 
frequent cleaning may be required due to excessive 
lint from carpeting, bedding, etc. It is 

IMPERATIVE

 that 

the unit’s control compartment, burner, and circulating 
air passageways 

BE KEPT CLEAN 

to provide for 

adequate combustion and ventilation air.

Always 

KEEP

 the appliance clear and free from 

combustible materials, gasoline, and other 

fl

 ammable 

vapors and liquids.

NEVER OBSTRUCT 

the 

fl

 ow of combustion and 

ventilation air. Keep the front of the appliance 

CLEAR

 

of all obstacles and materials for servicing and proper 
operation.

Due to the high temperature, the appliance should 
be 

LOCATED

 out of traf

fi

 c areas and away from 

furniture and draperies. Clothing or 

fl

 ammable material 

SHOULD NOT BE PLACED 

on or near the appliance.

This unit MUST be used with a vent system as 
described in this installation manual. 

NO

 

OTHER

 vent 

system or components 

MAY BE USED

.

This gas 

fi

 replace and vent assembly 

MUST

 be vented 

directly to the outside and 

MUST

 

NEVER

 be attached 

to a chimney serving a separate solid fuel burning 
appliance. Each gas appliance 

MUST USE 

a separate 

vent system. Common vent systems are 

PROHIBITED

.

INSPECT

 the external vent cap on a regular basis to 

make sure that no debris, plants, trees, shrubs are 
interfering with the air 

fl

 ow.

The glass door assembly 

MUST

 be in place and sealed 

before the unit can be placed into safe operation.

DO NOT OPERATE

 this appliance with the glass door 

removed, cracked, or broken. Replacement of the glass 
door should be performed by a licensed or quali

fi

 ed 

service person. 

DO NOT

 strike or slam the glass door.

The glass door assembly 

SHALL ONLY 

be replaced 

as a complete unit, as supplied by the 

fi

 replace 

manufacturer. 

NO SUBSTITUTE

 material may be used.

DO NOT USE 

abrasive cleaners on the glass door 

assembly. 

DO NOT ATTEMPT

 to clean the glass door 

when it is hot.

TURN OFF

 the gas before servicing this appliance. 

It is recommended that a quali

fi

 ed service technician 

perform an appliance check-up at the beginning of 
each heating season.

Any safety screen or guard removed for servicing 

MUST BE REPLACED 

before operating this appliance.

BE CAREFUL

 not to put any decorating objects 

sensitive to heat to close above or around the 

fi

 replace 

as it gets very hot when operating.

DO NOT 

use this heater as a temporary source of heat 

during construction.

NOTE:

 When operating your new 

fi

 replace for the 

fi

 rst time, some vapors may be released due to the burning 

of curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause 
the 

fl

 ames to be the full height of the 

fi

 rebox, or even slightly higher, for the 

fi

 rst few hours of operation. It is also 

possible that these vapors could set off any smoke detection alarms in the immediate vicinity. These vapors are 
quite normal on new appliances. We recommend opening a window to vent the room. After a few hours use, the 
vapors will have disappeared and the 

fl

 ames will be at their normal height.

Содержание 530XAN/XAP

Страница 1: ...Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified inst...

Страница 2: ...hould you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation...

Страница 3: ...onfigurations 13 Vertical Termination Installations 15 Appliance Preparation 17 Air Restrictors Installation 20 Remote Control Installation 21 Gas Supply Installation 22 Aeration Setting Check 23 Cera...

Страница 4: ...llation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate sol...

Страница 5: ...uipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requi...

Страница 6: ...side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the man...

Страница 7: ...30X engine is available in either natural gas or propane gas and comes equipped with either a simulated log or coal fuel bed in either fuel A pebble set is also offered as an optional feature See Opti...

Страница 8: ...pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the applia...

Страница 9: ...o prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cl...

Страница 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Страница 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Страница 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Страница 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Страница 14: ...ey systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ad...

Страница 15: ...ce the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Determine t...

Страница 16: ...s on to the appliance Drop the 3 dia flexible liners into the chimney from outside Fit the liners to the co linear adapter paying attention to inlet and exhaust and move the appliance to its proper po...

Страница 17: ...end of the burner Push in the lighting knob and turn counter clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield Window Removal...

Страница 18: ...r vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically inside t...

Страница 19: ...ter to the outer collar with two 6 thread cutting screws supplied 1 2 3 1 2 3 4 5 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top...

Страница 20: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Страница 21: ...wires are pointing up and slot in the board is in line with the tab on the wiring harness plug Connect wires as shown below Please note that the L connectors are different sizes the smaller one fits...

Страница 22: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Страница 23: ...n in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provided...

Страница 24: ...log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow nose...

Страница 25: ...the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Place...

Страница 26: ...liance and the remote control See the Lighting Instructions on page 30 of this manual for full details Aeration adjustment As described on page 23 the burner aeration is adjustable For the vast majori...

Страница 27: ...d damage See page 17 To refit the window place it centrally against the firebox while resting it on the support at the bottom of the firebox Pull the clamping bars forward and rotate inwards to secure...

Страница 28: ...ts the minutes Set the time Note You must start setting the time while the F is flashing If it stops flashing go back to 1 The display shows C 24 hour or F 12 hour To change the temperature hour displ...

Страница 29: ...P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning Press the TIMER button and hold it until P1 a...

Страница 30: ...2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force...

Страница 31: ...rofitted at a later date Bedroom Remote Kit 562BRK Automatic shut off remote control kit for bedroom installation Circulating Fan Kit 555CFK Having variable speed and temperature control it is designe...

Страница 32: ...Snorkel 14 Rise 982 4DT ST14 Snorkel 36 Rise 981 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 Co linear Flex Connector 923F Co axial to Co linear Adapter 923GCL 556CLA Co line...

Страница 33: ...hing 0 12 6 12 943 4DT AF6 SV4FA Roof Flashing 7 12 12 12 943S 4DT AF12 SV4B Flat Roof Flashing 943F SV4F Various Venting System Parts Wall Thimble 942 4DT WT SV4RSM Storm Collar 953 4DT SC SV4AC Deco...

Страница 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Страница 35: ...ate 4 coals 320B457 47 Wall mount plate 9000008 16 Restrictor plate 1 logs 320B396 48 Wiring harness 4000329 17 Restrictor plate 2 logs 320B397 49 Ceramic coal set 000B245 18 Restrictor plate 3 logs 3...

Страница 36: ...3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 44a 45 46 47 48 NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Replacem...

Отзывы: