Gas Supply Installation

It’s preferable to rough-in the gas line at this point before proceeding with the 

fi

 rebox installation.

The appliance is supplied for supply gas connection at the rear left corner of the case. Supply line connection to 
the inlet pipe of the appliance is 3/8”NPT (female).
Alternatively, the appliance inlet pipe may be removed and the supply line routed directly to the control unit 
having a 3/8” NPT female thread. Take care not to torque the valve or damage the wire connectors on the valve. 
An isolating valve could be 

fi

 tted within the appliance case. If the circulating fan is to be installed, be aware that 

the supply pipe should follow the route of the original appliance inlet pipe in order to clear the fan. If intending to 

fi

 t an internal isolating valve, check that it will be clear of the fan.

Use only new black iron or steel pipes or copper tubing if acceptable—check local codes. 

Note that in USA, 

copper tubing must be internally tinned for protection against sulfur compounds.

Unions in gas lines should be of ground joint type.
The gas supply line must be sized and installed to provide a supply of gas suf

fi

 cient to meet the maximum 

demand of the appliance without undue loss of pressure.
Sealant used must be resistant to the action of all gas constituents including LP gas. Sealant should be applied 
lightly to male threads to ensure excess sealant does not enter gas lines.
The supply line should include a manual shut-off valve and union to allow the appliance to be disconnected for 
servicing.
Pressure test the supply line for leaks.

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system 
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or less 
than 1/2 psig (3.5kPa).

Failure to either disconnect or isolate the appliance during 
pressure testing may result in regulator or valve damage. 
Consult your dealer in this case.
The minimum supply pressure is given in 

Specifi cations 

section of this manual.
All piping and connections must be tested for leaks after 
installation or servicing. All leaks must be corrected 
immediately.
When testing for leaks:

Make sure that the appliance is turned off.
Open the manual shut-off valve.
Test for leaks by applying a liquid detergent or soap 
solution to all joints. Bubbles forming indicate a gas 
leak. 

Never use an open 

fl

 ame to check for leaks

.

Correct any leak detected immediately.

The pressure test tapping locations are shown in 

fi

 gure above. A built-in non-adjustable regulator controls the 

burner manifold pressure. The correct pressure range is shown in the table in the 

Specifi cations 

section of 

this manual. The pressure check should be made with the burner alight and at its highest setting. See 

Lighting 

Instructions

 section for full operating details.





Содержание 530XAN/XAP

Страница 1: ...Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified inst...

Страница 2: ...hould you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation...

Страница 3: ...onfigurations 13 Vertical Termination Installations 15 Appliance Preparation 17 Air Restrictors Installation 20 Remote Control Installation 21 Gas Supply Installation 22 Aeration Setting Check 23 Cera...

Страница 4: ...llation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate sol...

Страница 5: ...uipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requi...

Страница 6: ...side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the man...

Страница 7: ...30X engine is available in either natural gas or propane gas and comes equipped with either a simulated log or coal fuel bed in either fuel A pebble set is also offered as an optional feature See Opti...

Страница 8: ...pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the applia...

Страница 9: ...o prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cl...

Страница 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Страница 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Страница 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Страница 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Страница 14: ...ey systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ad...

Страница 15: ...ce the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Determine t...

Страница 16: ...s on to the appliance Drop the 3 dia flexible liners into the chimney from outside Fit the liners to the co linear adapter paying attention to inlet and exhaust and move the appliance to its proper po...

Страница 17: ...end of the burner Push in the lighting knob and turn counter clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield Window Removal...

Страница 18: ...r vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically inside t...

Страница 19: ...ter to the outer collar with two 6 thread cutting screws supplied 1 2 3 1 2 3 4 5 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top...

Страница 20: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Страница 21: ...wires are pointing up and slot in the board is in line with the tab on the wiring harness plug Connect wires as shown below Please note that the L connectors are different sizes the smaller one fits...

Страница 22: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Страница 23: ...n in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provided...

Страница 24: ...log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow nose...

Страница 25: ...the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Place...

Страница 26: ...liance and the remote control See the Lighting Instructions on page 30 of this manual for full details Aeration adjustment As described on page 23 the burner aeration is adjustable For the vast majori...

Страница 27: ...d damage See page 17 To refit the window place it centrally against the firebox while resting it on the support at the bottom of the firebox Pull the clamping bars forward and rotate inwards to secure...

Страница 28: ...ts the minutes Set the time Note You must start setting the time while the F is flashing If it stops flashing go back to 1 The display shows C 24 hour or F 12 hour To change the temperature hour displ...

Страница 29: ...P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning Press the TIMER button and hold it until P1 a...

Страница 30: ...2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force...

Страница 31: ...rofitted at a later date Bedroom Remote Kit 562BRK Automatic shut off remote control kit for bedroom installation Circulating Fan Kit 555CFK Having variable speed and temperature control it is designe...

Страница 32: ...Snorkel 14 Rise 982 4DT ST14 Snorkel 36 Rise 981 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 Co linear Flex Connector 923F Co axial to Co linear Adapter 923GCL 556CLA Co line...

Страница 33: ...hing 0 12 6 12 943 4DT AF6 SV4FA Roof Flashing 7 12 12 12 943S 4DT AF12 SV4B Flat Roof Flashing 943F SV4F Various Venting System Parts Wall Thimble 942 4DT WT SV4RSM Storm Collar 953 4DT SC SV4AC Deco...

Страница 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Страница 35: ...ate 4 coals 320B457 47 Wall mount plate 9000008 16 Restrictor plate 1 logs 320B396 48 Wiring harness 4000329 17 Restrictor plate 2 logs 320B397 49 Ceramic coal set 000B245 18 Restrictor plate 3 logs 3...

Страница 36: ...3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 44a 45 46 47 48 NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Replacem...

Отзывы: