Proflame 2 

–NE2 / LPE2    

-IPI System Parts List-  

 

 IPI PROFLAME 2 - COMPONENT PARTS

 

 

PART NO. 

DESCRIPTION 

1. 

 

1005-P001SI 

Valve IPI Proflame PF2 885.001 NG - Stepper 

2. 

 

1005-P002SI 

Valve IPI Proflame PF2 885.002 LP - Stepper 

3. 

 

1005-P325SI 

Module IPI - Proflame 2 - 584.325 

4. 

 

1005-P627SI   

Module IPI 

– Proflame 2 - Basic - 584.627 

5. 

 

1005-P924SI 

Harness PF2 - 584.924 

6. 

 

GTMFL 

Transmitter- PF2 - 584.090 - WiFi Version 

6b.  1005-P042SI 

Transmitter- PF2 - 584.042 - Non-WiFi Version 

6c.  1005-P080SI 

Transmitter- PF2 - 584.080 - WiFi Version 

For Replacement Transmitters, Replace with Same Part Number 

7. 

 

584-PWR-C 

Wire Harness PF2 

– Power Cord 

8. 

 

584-X4P 

Terminal Block 

9. 

 

584-X10 

Wire Harness PF2 

10. 

 

584-ACC01-C 

Wire Harness PF2 - Fan/Light 

11. 

 

584-X8-B 

Wire Harness PF2 - Optional Reset Harness 

12. 

 

584-X12 

Optional Power Vent Harness 

IPI - PF1 and PF2 Common Components 

PART NO. 

DESCRIPTION 

13. 

 

1002-P033SI 

TC - Pilot Burner IPI (Assembled) NG 199.033 

14. 

 

1002-P047SI 

TC - Pilot Burner IPI (Assembled) LP 199.047 

15. 

 

1001-P166SI 

TC - Orifice Pilot NG 977.166 #62  (IPI) 

16. 

 

1001-P168SI 

TC - Orifice Pilot LP 977.168 #35 (IPI) 

17. 

 

1001-P280SI 

TC - Tubing W/Fittings 1/8   2.182.280 

18. 

 

1002-P012SI 

IPI Stepper Kit - LP 907.012        

19. 

 

1002-P013SI 

IPI Stepper Kit - NG 907.013      

20. 

 

1002-P014SI 

IPI Reg Kit - LP Hi-Lo 907.014      

21. 

 

1002-P016SI 

IPI Reg Kit - NG Hi-Lo 907.016 

22. 

 

1002-P017SI 

TC - Electrode Cable & Sparker IPI 915.017 24" 

23. 

 

1002-P119SI 

TC - Electrode Cable & Sparker IPI 35" 

(Infinite, ZCVRB47, VRB46) 

24. 

 

1002-P12BH 

IPI Battery Housing 12bh347-Gr         

25. 

 

1002-P903SI 

TC - Electrode Flame Sense IPI 007.253/915.903 
24" 

26. 

 

1002-P910SI 

TC - Electrode Flame Sense 35" 

(Infinite, ZCVRB47, VRB46) 

 

Proflame Transmitter 
0.584.042 - Non-WiFi 

NOTE:

 Fan and / or Light Options are not available on some 

fireplaces. 

Check with your dealer.

 

3 & 4 

6b 

11 

12 

P2  

CONVERSION

 

P1 

CONVERSION

 

1&2 

10 

10 

Proflame Transmitter 
0.584.090 - WiFi 
Current Version 

6c 

Proflame Transmitter 
0.584.080 - WiFi 

13 

44

Содержание Marquis MQZDV3318

Страница 1: ...future reference A Division of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada December 14 2021 Part 3318MQ MAN17 This appliance may be installed in an afte...

Страница 2: ...MQLOGC22 for MQZDV3318 3622 22 23 MQLOGC23 4 Piece Driftwood Log Set 24 MQRSP5 for MQZDV3318 3622 25 26 3318 3622 Door and Glass Information 27 Burner System Gas Line Installation 28 Burner System Re...

Страница 3: ...Fireplace 53 Z47ST24 Z47ST36 Horizontal Snorkel Terminations 54 Venting Straight Up Through Roof 55 56 Vertical Venting over 15 Feet 57 Glass Safety Termination Cap Safety 58 Approved for Power Vent P...

Страница 4: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Страница 5: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Страница 6: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Страница 7: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 8: ...n National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to in...

Страница 9: ...all screws to pop or pull due to wood studs drying out Minimum of 1 2 CONCRETE BOARD cement board this non combustible panel is ULC listed as a wall shield floor protector and fasten to the entire per...

Страница 10: ...mal shock Take care to prevent water from contacting the fireplace especially if it is hot See Through Units are suitable for an outdoor location but not on the outside wall of a house or other struct...

Страница 11: ...nstallation with a top vent is possible as long as the horizon tal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall corn...

Страница 12: ...t be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the ceili...

Страница 13: ...Z33CVCK Framing and Facing Requirements MQZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround 13...

Страница 14: ...lied screws FIG 1 For ZDV6000 ZDV3320 MQRB3328 models use the larger 8 standoffs On the ZDV3318 unit remove the large 8 standoffs 3 Hang CVCK on top of fireplace retainer tabs and rotate down into pos...

Страница 15: ...DV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combust...

Страница 16: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Страница 17: ...es 5 inches 12 7 cm All Vent Systems Enclosure over 43inches 2 1 2 inches 6 4 cm All Vent Systems Systems Top of Horizontal Pipe 1 1 2 inches 3 8 cm All Vent Systems Side Bottom of Horizontal Pipe 1 i...

Страница 18: ...Surround so that the Surround Ledge is resting on top of the CVCK Deflector Lip 3 Align the Mounting Screw Holes and fasten the Surround in place with the supplied screws Note It may be necessary to l...

Страница 19: ...the unit reaches operating temperature approximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the wall switch fully counter clockwise 5 To set the minim...

Страница 20: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Страница 21: ...hile placing the bottom edge over the front ledge of the firebox Then rotate the panel upright and slide it back towards the rear liner panel Make sure the top of the side panel is engaged with the to...

Страница 22: ...rock wool on burner as shown in step 1 being sure to leave the multiple porting areas open For Lp only the multiple porting areas can be completely covered Do not cover the Rear Porting areas with ro...

Страница 23: ...EP 4 Place Log 4 into place as shown Do Not place directly over top of the multiple porting area on the left side STEP 5 Fill in the rest of the burner pan and ember plates with lava rock and vermicul...

Страница 24: ...e Lava Rock around sides of Burner Tube LOG 1 LOG 2 LOG 3 LOG 4 LOG 1 LOG 2 LOG 3 LOG 4 Lava Rock Lava Rock Glowing Embers Lava Rock Base Unit Place Glowing Embers on sides and front of Burner Tube Do...

Страница 25: ...the 2 ember plates once the grate bar is removed The 2 screws removed must be re installed once the grate bar is removed Step 3 Using the left ember plate mounting bracket slide the left ember plate...

Страница 26: ...that they are crossing over the single line porting MQRSP5 finished setup and burn Step 8 Place rock 3 and rock 1 into position as shown to complete the setup Lava rock and vermiculite are optional f...

Страница 27: ...aution when removing broken glass wear gloves Removal of the Glass Door ZDV3318 MQZDV3318 1 Unlatch the two latches located behind the upper grill 2 To remove pull frame forward and lift from bottom d...

Страница 28: ...during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve d...

Страница 29: ...e of gas valve 4 Remove screws from perimeter of burner system pan Lift pan at one back corner and rotate pan up from back of firebox Make sure when tilting up and removing burner system that all fan...

Страница 30: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Страница 31: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Страница 32: ...e picture Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 3318 CKLP Propane Conversion Millivolt 1001 P16...

Страница 33: ...steps to reassemble burner system IMPORTANT Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTING WARNING This conversion kit shall be installed by a qualif...

Страница 34: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Страница 35: ...Gas Conversion for Modulator PART C 35...

Страница 36: ...ppliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allotted time period Th...

Страница 37: ...hat the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of...

Страница 38: ...P 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P01...

Страница 39: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 39...

Страница 40: ...s with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown SCHEMATIC PICTURE NOTE Fan Op...

Страница 41: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Страница 42: ...lities Refer to the fan installation removal section for fan installation NOTE Fan Option is not available on some models of fireplace Check with your dealer NOTE This Configuration is not available o...

Страница 43: ...power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Wait five 5 minutes to clear out any gas Then...

Страница 44: ...13 1002 P033SI TC Pilot Burner IPI Assembled NG 199 033 14 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 15 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 16 1001 P168SI TC Orifice Pilot LP 977...

Страница 45: ...s required The following sequence must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The P...

Страница 46: ...the main burner has been cycled ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON...

Страница 47: ...Proflame 2 Remote Control 47...

Страница 48: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode Halogen lights only 48...

Страница 49: ...iring Diagram For use with all Kingsman manufactured IPI Proflame 2 models for all types of gas noted on rating plate Supply 120VAC 60Hz 3A 6 volts battery backup Pour utilisation avec tous les mod le...

Страница 50: ...3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m Notes 2 M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm N Where a ve...

Страница 51: ...Fig 1 Horizontal runs require support metal straps every 2 feet In offset installation support straps should be used to stabilize pipe Expand 4 and 7 flex pipe to the point that the 7 protrudes approx...

Страница 52: ...to wall using caulking around the wall thimble to weather proof After installing the vent termination double check to make sure the pipe extends properly through wall thimble and into vent termination...

Страница 53: ...ht of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertic...

Страница 54: ...w well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination Do not enclose the Snorkel within a wa...

Страница 55: ...rulers or by using a roof pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the sh...

Страница 56: ...upport configuration B Flex bend configuration C Termination mounting Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requireme...

Страница 57: ...INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screws a...

Страница 58: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 59: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Страница 60: ...d for entire installation order Z47PVA Note Must use a one foot section of 5 8 DV hard pipe connected to the power vent on all installations Termination End Z47PVA Flex Pipe Adapter Kit to adapt flex...

Страница 61: ...P Conversion Kit 3318 CKLP Propane Conversion Kit Millivolt 3318 CKNG Natural Gas Conversion Kit Millivolt 3318 CKLPI Propane Conversion Kit IPI 3318 CKNGI Natural Gas Conversion Kit IPI Accessories Z...

Страница 62: ...FDVVT40 Vertical Vent Termination converts from 15 40 to 15 and under FDVHT Horizontal Vent Termination FDVHSQ Horizontal Square Termination FDVHSCU Safety Cage for Horizontal Termination Z47ST24 Hori...

Страница 63: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...

Страница 64: ...hemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchi...

Отзывы: