Cold Climates
– CPI Setting - Proflame 2 Remote Control
Use the CPI setting during cold
weather,
otherwise the fireplace
may have a hard time starting up
and establishing a flame.
The
CPI
(Continuous Pilot Ignition) setting
will keep the firebox and fireplace
exhaust vent warm during cold
weather. When the firebox and
exhaust vent are warm, exhaust
gasses will readily flow out of the firebox.
If the firebox and venting are too cold, there is resistance due to the heavy cushion of cold air, and combustion gasses may
not rise into the exhaust vent, thus causing the fireplace to cycle or
Lockout
(if this happens see
Lockout Reset
Procedures
below).
NOTE:
The pilot system for this appliance may be equipped with a
Seven Day Timer
, in which case the pilot flame will be
extinguished if the main burner has not been turned ON for seven days. This Seven Day Cycle is reset every time the main
burner is cycled ON / OFF and the pilot remains lit. If more than seven days has passed since the main burner has been
cycled ON / OFF and the pilot is also out, follow the procedures described in this manual to light the pilot.
To switch from IPI to CPI Mode:
1.
Turn the fireplace OFF using the
ON / OFF Key
.
2.
Press the
Mode Key
. Display will appear as below.
3.
Press UP on the
UP / DOWN
Arrow Key
.
Display will show
CPI.
The module in the fireplace will
beep once to confirm command.
TO RETURN TO IPI
(INTERMITTENT PILOT) MODE:
Repeat steps one and two, and then press
DOWN on the
UP / DOWN Arrow Key
.
The module in the fireplace will beep once to
confirm command.
Lockout Reset Procedures
– Proflame 2
If the fireplace has cycled too many times
in a short period of time, it will shut down
and become unresponsive to any new
command.
The LED light on the Proflame 2 module
in the fireplace will be flashing red.
This condition is a
Lockout
state.
Lockout Reset Procedure:
1. Disconnect power from the Proflame 2 module in the fireplace for 10
seconds. This includes removing the backup batteries.
2. Once the 10 second interval has passed, reconnect power and reinstall
backup batteries. The pilot should now try to light.
3. If the fireplace does not come on, call your fireplace technician.