Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

worksurface,

22 deep

worksurface, 22 deep

22 splice plate

worksurface,

24-30 deep

worksurface, 24-30 deep

#12 x  /

3

4

screws

Standard Cantilever Bracket 

Installation with 22” Deep 

Worksurface

Note:

 When 22” deep 

worksurfaces are installed 

adjacent to each other, right- and 

left-hand cantilever brackets will 

be installed side-to-side with the 

flat faces touching. Above the 

cantilever brackets, and spanning 

under both worksurfaces, a 22” 

splice plate must be installed 

between the cantilever brackets 

and the adjoining worksurface 

pairs to keep worksurface tops 

aligned (Figure 2).

1. Install standard cantilever 

brackets to Unite panels as 

outlined in steps 1-4 (previous 

page) (Figure 1).

2. Where two worksurfces will meet 

on cantilever brackets, set a 22” 

splice plate onto the left- and 

right-hand cantilever bracket 

pair between panels. Align 

the support bracket mounting 

holes over the cantilever bracket 

mounting holes, then carefully 

place each worksurface onto 

cantilever brackets and align 

mounting holes of brackets to 

pre-drilled holes in underside of 

worksurface. Secure using two 

#12 x 

3

/

4

” screws per bracket. 

Take care to not over-tighten the 

screws (Figures 1 & 2). 

Standard Cantilever Bracket 

Installation with 24-30” Deep 

Worksurface

Note:

 When 24-30” deep 

worksurfaces are installed 

adjacent to each other, right- and 

left-hand cantilever brackets will 

be installed side-to-side with 

the flat faces touching. A small 

worksurface splice plate must be 

installed between the adjoining 

worksurface pairs, in front of the 

cantilever bracket pair to keep 

worksurface tops aligned 

(Figure 3).

1. Install standard cantilever brackets 

to Unite panels as outlined in 

steps 1-4 (previous page) 

  (Figure 1).

2. Carefully place worksurfaces onto 

installed cantilever brackets and 

align mounting holes of brackets 

to pre-drilled holes in underside 

of worksurfaces. Secure using 

two #12 x 

3

/

4

” screws per bracket. 

Take care to not over-tighten the 

screws (Figure 3). 

3. To keep worksurfaces level, install 

a small splice plate between 

worksurfaces as illustrated. 

Position the splice plate centered 

under the installed worksurfaces 

and use mounting holes as 

template, then mark mounting 

hole locations. Pre-drill 

1

/

8

” 

diameter mounting holes to a 

depth of 

1

/

2

” only, taking care 

to not drill too deep which may 

damage the worksurface 

  (Figure 5). 

4. Install small splice plate to 

underside of worksurfaces using 

four #12 x 

3

/

4

” screws. Take care 

to not over-tighten screws 

  (Figure 5).

Содержание Unite System

Страница 1: ...Assembly Instructions Unite Panel System Worksurfaces February 2021...

Страница 2: ...Change of Height Bracket Overview 10 Corner Change of Height Brackets 11 Peninsula Conference End Worksurfaces 13 Worksurfaces to Panel Mounted Support Leg 15 Worksurface with Pedestal Support Instal...

Страница 3: ...e panel and the left handed bracket is at the left The outer face of an installed cantilever bracket should appear flush with the edge of the panel surface and the mounting flange must face inward Fig...

Страница 4: ...surface onto cantilever brackets and align mounting holes of brackets to pre drilled holes in underside of worksurface Secure using two 12 x 3 4 screws per bracket Take care to not over tighten the sc...

Страница 5: ...hen properly installed will span over the beveled gap Figure 4 1 Install standard cantilever brackets to Unite panels as outlined in steps 1 4 page 3 to the locations outlined in your space planning l...

Страница 6: ...kets to pre drilled holes in underside of worksurfaces Insert two 12 x 3 4 screws only half way through each bracket into the worksurface except at the location where a 22 splice plate will go 3 Where...

Страница 7: ...ample The typical KI worksurface thickness is 11 8 therefore the installed Unite cantilever bracket should measure 277 8 from top of bracket to the floor 3 To install the support bracket first orient...

Страница 8: ...he floor 3 To install design bracket first rotate the front of the bracket up as illustrated and insert the top anti dislodge tooth into the panel module slotting at the appropriate height Push up whe...

Страница 9: ...ed worksurface Using the properly positioned attachment plate as a template mark the center of all attachment hole locations to the underside of the peninsula surface Remove the plate and using a dril...

Страница 10: ...rface Change of height brackets are available in different lengths for worksurfaces from 18 to 30 including KN 1 Select the bracket height location based on the desired worksurface height Typical work...

Страница 11: ...2 Install the lower worksurface completely Per the space planning layout the lower worksurface depth must match the width of the adjacent panel The lower workurface must be installed with an approved...

Страница 12: ...ss through taking care to not damage the panel material or the lower worksurface Figure 15 6 At the non change of height end align the pre drilled mounting holes in the worksurface underside with the...

Страница 13: ...age If a support leg is used skip now to step 3 then continue on to step 4 next page 2 Position both post legs onto the underside of the worksurface square to the corner with the edge of the mounting...

Страница 14: ...worksurface right side up next to the adjoining worksurface and position the panel mount end onto the mounting brackets installed to the panel edge support bracket and design bracket illustrated Alig...

Страница 15: ...al floor location 1 Per space planning layout determine which right left center support legs are to install where along the run of panels and stage accordingly Figure 19 Note The bottom of the panel m...

Страница 16: ...ent and securing of lock brackets must be done only after all panel mounted support legs are installed Note Standard 2 height adjustable glides ship installed in support legs If more leveling height i...

Страница 17: ...edestal to the panel wall depending on worksurface type depth and according to space planning layout A support bracket with no spacer is only used on 22 deep worksurfaces and 24 deep with Knife Edge B...

Страница 18: ...or right hand installations align the bracket with the right side of the cabinet Figure 23 2 Using the four 10 x 3 4 self drilling sheet metal screws carefully secure the bracket to the cabinet Figure...

Страница 19: ...pport brackets are used in this typical configuration Your configuration may vary Please see pages 3 7 for proper installation Pedestal to Panel Installation Note All pedestals mount to the panel in t...

Страница 20: ...2 into underside of worksurface Take care to not drill too deep 4 To install pedestal to underside of worksurface align pre drilled holes in the worksurface with mounting holes of the pedestal Take ca...

Страница 21: ...2 Replace the attachment plate over the pre drilled holes and secure plate to underside of adjacent worksurface using 12 x 3 4 screws Take care to not over tighten screws Figure 27 3 Place pedestal to...

Страница 22: ...gh the pre drilled holes on each corner of the pedestal Figure 28 5 To keep worksurfaces level install a small splice plate between adjacent worksurfaces as illustrated Perpendicular 24 30 Note If ins...

Страница 23: ...the same as Unite panels and returns Overheads can be used with similar rules as Unite panel loading Note When more than one worksurface is used between two gallery panels a worksurface edge support...

Страница 24: ...Street P O Box 8100 Green Bay Wisconsin 54308 8100 1 800 424 2432 www ki com KI is a registered trademark of Krueger International Inc 2021 Krueger International Inc All Rights Reserved Code KI AI 00...

Отзывы: