background image

12

Unite

®

 Panel System - Worksurface Installation

Assembly Instructions

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

#12 x  /

3

4

screws

#12 x  /

3

4

screws

Corner Change-of-Height 

Brackets (cont.)

5. Turn the upper worksurface to 

the upright position and set into 

place on the lower worksurface 

and cantilever bracket, carefully 

guiding the installed L-bracket 

between the edge of the lower 

worksurface and the Unite panel. 

Press in on the panel to allow the 

L-bracket to pass through, taking 

care to not damage the panel 

material or the lower worksurface 

(Figure 15).

6. At the non change-of-height end, 

align the pre-drilled mounting 

holes in the worksurface 

underside with the holes in the 

cantilever bracket and secure with 

two #12 x 

3

/

4

” screws to secure 

Take care to not over-tighten the 

screws (Figure 15).

7. Working under the lower 

worksurface at the 

  change-of-height end, engage 

the tang of the lock bracket into 

the slot of the L-bracket that 

protrudes below the worksurface 

underside. Gently push in on the 

tile material to give the tang of 

the lock bracket room to rotate up 

to be flush with the worksurface 

underside. Carefully drill two 

1

/

8

” diameter pilot holes to no 

more than 

1

/

2

” deep through 

the center of the lock bracket’s 

mounting holes. Take care to not 

drill too deep to avoid damage 

to the worksurface. Secure the 

lock bracket using two #12 x 

3

/

4

” 

screws (Detail C).

Содержание Unite System

Страница 1: ...Assembly Instructions Unite Panel System Worksurfaces February 2021...

Страница 2: ...Change of Height Bracket Overview 10 Corner Change of Height Brackets 11 Peninsula Conference End Worksurfaces 13 Worksurfaces to Panel Mounted Support Leg 15 Worksurface with Pedestal Support Instal...

Страница 3: ...e panel and the left handed bracket is at the left The outer face of an installed cantilever bracket should appear flush with the edge of the panel surface and the mounting flange must face inward Fig...

Страница 4: ...surface onto cantilever brackets and align mounting holes of brackets to pre drilled holes in underside of worksurface Secure using two 12 x 3 4 screws per bracket Take care to not over tighten the sc...

Страница 5: ...hen properly installed will span over the beveled gap Figure 4 1 Install standard cantilever brackets to Unite panels as outlined in steps 1 4 page 3 to the locations outlined in your space planning l...

Страница 6: ...kets to pre drilled holes in underside of worksurfaces Insert two 12 x 3 4 screws only half way through each bracket into the worksurface except at the location where a 22 splice plate will go 3 Where...

Страница 7: ...ample The typical KI worksurface thickness is 11 8 therefore the installed Unite cantilever bracket should measure 277 8 from top of bracket to the floor 3 To install the support bracket first orient...

Страница 8: ...he floor 3 To install design bracket first rotate the front of the bracket up as illustrated and insert the top anti dislodge tooth into the panel module slotting at the appropriate height Push up whe...

Страница 9: ...ed worksurface Using the properly positioned attachment plate as a template mark the center of all attachment hole locations to the underside of the peninsula surface Remove the plate and using a dril...

Страница 10: ...rface Change of height brackets are available in different lengths for worksurfaces from 18 to 30 including KN 1 Select the bracket height location based on the desired worksurface height Typical work...

Страница 11: ...2 Install the lower worksurface completely Per the space planning layout the lower worksurface depth must match the width of the adjacent panel The lower workurface must be installed with an approved...

Страница 12: ...ss through taking care to not damage the panel material or the lower worksurface Figure 15 6 At the non change of height end align the pre drilled mounting holes in the worksurface underside with the...

Страница 13: ...age If a support leg is used skip now to step 3 then continue on to step 4 next page 2 Position both post legs onto the underside of the worksurface square to the corner with the edge of the mounting...

Страница 14: ...worksurface right side up next to the adjoining worksurface and position the panel mount end onto the mounting brackets installed to the panel edge support bracket and design bracket illustrated Alig...

Страница 15: ...al floor location 1 Per space planning layout determine which right left center support legs are to install where along the run of panels and stage accordingly Figure 19 Note The bottom of the panel m...

Страница 16: ...ent and securing of lock brackets must be done only after all panel mounted support legs are installed Note Standard 2 height adjustable glides ship installed in support legs If more leveling height i...

Страница 17: ...edestal to the panel wall depending on worksurface type depth and according to space planning layout A support bracket with no spacer is only used on 22 deep worksurfaces and 24 deep with Knife Edge B...

Страница 18: ...or right hand installations align the bracket with the right side of the cabinet Figure 23 2 Using the four 10 x 3 4 self drilling sheet metal screws carefully secure the bracket to the cabinet Figure...

Страница 19: ...pport brackets are used in this typical configuration Your configuration may vary Please see pages 3 7 for proper installation Pedestal to Panel Installation Note All pedestals mount to the panel in t...

Страница 20: ...2 into underside of worksurface Take care to not drill too deep 4 To install pedestal to underside of worksurface align pre drilled holes in the worksurface with mounting holes of the pedestal Take ca...

Страница 21: ...2 Replace the attachment plate over the pre drilled holes and secure plate to underside of adjacent worksurface using 12 x 3 4 screws Take care to not over tighten screws Figure 27 3 Place pedestal to...

Страница 22: ...gh the pre drilled holes on each corner of the pedestal Figure 28 5 To keep worksurfaces level install a small splice plate between adjacent worksurfaces as illustrated Perpendicular 24 30 Note If ins...

Страница 23: ...the same as Unite panels and returns Overheads can be used with similar rules as Unite panel loading Note When more than one worksurface is used between two gallery panels a worksurface edge support...

Страница 24: ...Street P O Box 8100 Green Bay Wisconsin 54308 8100 1 800 424 2432 www ki com KI is a registered trademark of Krueger International Inc 2021 Krueger International Inc All Rights Reserved Code KI AI 00...

Отзывы: