Chapter 2: Preparing for Use
Installing application programs on Infiniium
35
Installing application programs on Infiniium
Infiniium is an open Windows system. This allows you to install your own application
software. Keysight has verified that the following applications are compatible with the
Infiniium oscilloscope application.
• Keysight Vector Signal Analysis
• Keysight VEE Pro
• Amherst Systems Oscilloscope Tools
• Microsoft Office 2000
• MathWorks MATLAB
• Mathsoft MathCad 2001i
• McAfee VirusScan
• Symantec Norton AntiVirus
If you install an application other than those which Keysight has tested, it is possible
that it could break the oscilloscope application. This would require you to reinstall the
oscilloscope application. Refer to the
Infiniium Oscilloscope User’s Quick Start Guide
for instructions on reinstalling the oscilloscope application.
Changing Windows System Settings
There are several Windows System settings that can be changed to suit your own
personal preferences. However, there are some system settings that you should avoid
changing because it will interfere with the proper operation of the oscilloscope.
• Do not change the Power Options.
• Do not change the System Properties Hardware Tab settings.
• Do not change the System Properties Advanced Tab settings.
• Do not change the Regional and Language Options Advanced Tab settings.
• Do not remove Fonts.
• Display Settings
• Do not change or turn off the default screen saver. The screen saver turns off the
display’s backlights, extending their life.
• Do not change the screen resolution or the color quality using the Control Panel
Display Settings. You may modify display settings by double- clicking the Intel Graphics
Media Accelerator Driver icon in the System tray.
• Do not modify the Advanced settings.
• Do not use the Administrative Tools to enable or disable Internet Information
Services (Web Server). Use the Infiniium Web Control dialog box to enable or
disable the Web Server.
Before installing any software, you should exit the oscilloscope application.
Before changing any Windows System settings outside of the oscilloscope
application you should Exit the oscilloscope application.
Содержание Infiniium 8000 Series
Страница 6: ...6...
Страница 31: ...Chapter 2 Preparing for Use Digital probe lead set 31 Data Sheets Demonstrations Catalogs...
Страница 66: ...Chapter 3 Testing Performance Performance Test Record 66...
Страница 140: ...Chapter 7 Replaceable Parts Exploded Views 140 Exploded Views Front Frame and Front Panel...
Страница 141: ...Chapter 7 Replaceable Parts Exploded Views 141 Fan and Acquisition Assembly...
Страница 142: ...Chapter 7 Replaceable Parts Exploded Views 142 Power Supply and PC Motherboard Without Option 017...
Страница 143: ...Chapter 7 Replaceable Parts Exploded Views 143 Power Supply and PC Motherboard With Option 017...
Страница 144: ...Chapter 7 Replaceable Parts Exploded Views 144 Sleeve and Accessory Pouch...
Страница 150: ...Chapter 8 Theory of Operation 150 Figure 8 1 Oscilloscope Block Diagram...
Страница 158: ...158...
Страница 160: ...160 Index...