15 LTR TRUNKING
46
Confidential
FUNC (K)/Ver. 1.01
15.1.8 Time-out Timer (Dispatch)
The Time-out Timer (Dispatch) is the maximum
continuous transmission time to communicate using the
Dispatch ID.
(Refer to 9.2.1 Time-out Timer (Dispatch)
The maximum continuous transmission time using a
Dispatch ID can be configured by using KPG-101D.
Configuration using KPG-101D
• Configuring the Time-out Timer (Dispatch) (Refer
to FPRG 6.3.8 Time-out Timer (Dispatch).)
15.1.9 Time-out Timer (Telephone)
The Time-out Timer (Telephone) is the maximum
continuous transmission time to communicate using the
Telephone ID.
(Refer to 9.2.2 Time-out Timer
The maximum continuous transmission time using a
Telephone ID can be configured by using KPG-101D.
Configuration using KPG-101D
• Configuring the Time-out Timer (Telephone)
(Refer to FPRG 6.3.9 Time-out Timer
(Telephone).)
15.1.10 Audio Control
Audio Control can be used to configure conditions for the
transceiver to unmute with the LTR ID and Optional
Signaling.
(Refer to 16.3 Signaling (Audio Control) on
Audio Control can be configured for each zone by using
KPG-101D.
Configuration using KPG-101D
• Configuring the Audio Control (Refer to FPRG
6.3.10 Audio Control.)
15.1.11 Encode Data Type
Encode Data Type can be used to invert the logic of the
LTR Message to be sent.
Encode Data Type can be configured by using
KPG-101D.
Configuration using KPG-101D
• Configuring the Encode Data Type (Refer to
FPRG 6.3.11 Encode Data Type.)
15.1.12 Zone Add
Zone Add can be used to add a zone to the scan list by
using KPG-101D.
Configuration using KPG-101D
• Configuring the Zone Add (Refer to FPRG 6.3.12
Zone Add.)
15.1.13 Scan List
Scan List can be configured for each zone in conjunction
with the Scan List Table configuration by using KPG-101D.
Configuration using KPG-101D
• Configuring the Scan List (Refer to FPRG 6.3.13
Scan List and FPRG 6.3.15 Scan List Table
Window.)
15.1.14 Auto Telephone Search
Auto Telephone Search can be used to search for an
available RIC repeater and automatically connect to the
repeater.
Zones that meet the following conditions are targeted for
the search. If no zone matches the following conditions,
the transceiver emits the Deny Tone. In this case, the
transceiver does not execute the Auto Telephone Search
function.
• Zones in which “Yes” is selected from the
Zone Edit
window >
Auto Telephone Search
dropdown list.
• Zones with at least 1 repeater in which “Yes” is
selected from the
Repeater Information
window >
Telephone Repeater
dropdown list.
• Zones in which Group ID is configured in the
Zone
Edit
window >
Telephone (Block ID)
edit box and
there is at least 1 Group ID in the configured range.
A zone can be added to the Auto Telephone Search List
by using KPG-101D.
Note:
The zone from which Auto Telephone Search starts is
always searched.
Configuration using KPG-101D
• Configuring the Auto Telephone Search (Refer to
FPRG 6.3.16 Auto Telephone Search.)
• Assigning functions to the
PF
keys (Refer to
FPRG 6.8 Key Assignment.)