19 2-TONE
FUNC (K)/Ver. 1.01
Confidential
79
Alert Tone
Alert Tone can be used to configure the Alert Tone
emitted when the transceiver receives a call with
2-tone.
Alert Tone can be selected from 8 tones configured for
the Alert Tone Pattern.
(Refer to 4.4 Alert Tone Pattern
Configuration using KPG-101D
•
Configuring the Call Format (Refer to FPRG
6.11.2 Decode Tab - Call Format.)
•
Configuring the Transpond (Refer to FPRG 6.11.2
Decode Tab - Transpond.)
•
Configuring the Alert Tone (Refer to FPRG 6.11.2
Decode Tab - Alert Tone.)
19.3.2 A Tone/ B Tone/ C Tone/
D Tone
This function can be used to select the tone frequency for
A Tone, B Tone, C Tone and D Tone. The frequency can
be configured between 288.5 and 3106.0 Hz.
Configuration using KPG-101D
•
Configuring the A Tone, B Tone, C Tone and D
Tone (Refer to FPRG 6.11.2 Decode Tab - A
Tone, 6.11.2 Decode Tab - B Tone, 6.11.2 Decode
Tab - C Tone and 6.11.2 Decode Tab - D Tone.)
19.3.3 Auto Reset Timer
Auto Reset Timer controls the duration from when the
DTMF code matches to when the code is automatically
reset.
The Auto Reset Timer can be configured by using KPG-
101D. Transceiver operation after the Auto Reset Timer
expires can also be configured.
Table 19-4 Auto Reset Timer Operation
Table 19-5 Transceiver Operation after the
Auto Reset Timer Expires
Configuration using KPG-101D
•
Configuring the Auto Reset Timer (Refer to FPRG
6.11.2 Decode Tab - Auto Reset Timer.)
•
Configuring the LED (Refer to FPRG 6.11.2
Decode Tab - LED.)
•
Configuring the Alert (Refer to FPRG 6.11.2
Decode Tab - Alert Tone.)
•
Configuring the Monitor (Refer to FPRG 6.11.2
Decode Tab - Monitor.)
19.3.4 Clear to Transpond
Clear to Transpond forces the transceiver to wait while
other users are using a channel before starting to
transpond.
Clear to Transpond can configured to be enabled or
disabled by using KPG-101D.
Configuration using KPG-101D
•
Configuring the Clear to Transpond (Refer to
FPRG 6.11.2 Decode Tab - Clear to Transpond.)
19.3.5 Selective Call Alert LED
Selective Call Alert LED can be used to make the
Selective Call Alert LED blink when the transceiver
receives a code.
Selective Call Alert LED can be configured to be enabled
or disabled by using KPG-101D.
Configuration Operation
Off
The Auto Reset Timer does not activate.
1 to 300 s
LED, Alert Tone, Monitor, and the display
return to their previous statuses when
configured time elapses.
Item
Operation
LED
The Selective Call Alert LED stops blinking
when the Auto Reset Timer expires.
Alert Tone
The transceiver stops intermittently emitting
the Alert Tone when the Auto Reset Timer
expires.
Monitor
The matching status of the 2-tone is reset
when the Auto Reset Timer expires.