Listings
87
Analog Outputs
Two current outputs:
4-20 mA passive, two-wire, isolated
Resolution: 14
bit
Linearity:
± 0.05% of full scale
Temperature drift:
0.05% per 10K
Load: <
620
Ω
(at 24V supply)
Output value:
flow rate, job total, density or temperature
Pulse Output
Frequency range:
0.5 -10,000 Hz
Output signal:
active push pull output of flow rate and / or cycle output
Digital I/O
Status output type
push pull
Low / high level
1V / 23V @ 24Vsupply, 10k
Ω
load
Allowed load current
20mA max.
Output signal
Programmable
Control input type
Active high
Threshold voltage
6.5V
Input current
0.1mA @ 6.5V, 0.2mA @ 24V Vin
Input signal
Programmable
Содержание TRICOR TCE80 -E Series
Страница 1: ...Certified according to DIN ISO 9001 Manual TRICOR Coriolis Mass Flow Meter ...
Страница 2: ...SW Version Main V2 0x Display V2 0x Manual Revision 2 1 ...
Страница 90: ...Listings 90 Fig 22 Dimensions TCM5500 C through TCM65k C Fig 23 Dimensions TCM5500 E through TCM65k E ...
Страница 92: ...Listings 92 Remote meter Fig 24 Dimensions TCM A Remote wall mounted electronics Fig 25 Dimensions TCE8000 W ...
Страница 93: ...Listings 93 Fig 26 Dimensions TCE8000 E except A Fig 27 Dimensions TCE8000 E A ...
Страница 98: ...Contact Copyright KEM Subject to change without notice ES Rev 002 23 01 2012 ...