7.3.2 Ex Data TCM Transducer
TCM0325 TCM0650 TCM1550 TCM3100 TCM5500 TCM7900 TCM28k TCM65k
Driver coil
Vmax (V)
35
35
35
Imax (mA)
100
100
100
Pmax (W)
0.5
0.75
1.4
Ri (Ohm)
55
116
116
L (mH)
2.77
1.85
7.0
C (nF)
<< 1
<< 1
<< 1
Sensor coil
Vmax (V)
35
35
35
Imax (mA)
100
100
100
Pmax (W)
0.5
0.75
0.75
Ri (Ohm)
55
116
116
L (mH)
2.77
1.85
1.85
C (nF)
<< 1
<< 1
<< 1
Pt1000
Vmax (V)
12
Imax (mA)
60
Pmax (W)
0.2
Ri (Ohm)
> 900
L (mH)
<< 0.1
C (nF)
<< 1
Temperature
Medium temp. standard
≤
70°C (T4),
≤
100°C (T3)
Medium temp. „high temp“
≤
70°C (T4),
≤
135°C (T3),
≤
150°C (T2)