Installation
35
Fig. 16: Wiring diagram for power connections, DC operation
Terminal Description
50
Positive supply Voltage, 24V ±20%, referred to pin 51
51
Ground potential for supply voltage
52 Protective
ground
The ground terminals 8 and 51 are internally connected together.
Ground and protective ground are internally connected via a 1k
Ω
resistor. The resistor will thermally withstand a
potential difference of up to 30V between PE and GND but for proper operation this difference should be limited to
5V.
3.2.4.2
100 to 240V AC Mains Supply
The AC version of the TCE requires a nominal power supply of 100 – 240V AC and operates over a range of 90 –
264V AC.
The power supply input of the TCE is protected by a 1A slow blow fuse. As a protection against fire in case of a
short in the supply cable, the output of the power supply must be equipped with a fuse with a rating not higher
than the current carrying capacity of the cable used.
For the mains powered units a good connection of PE is mandatory. The cross section of the PE cable should be
at least the cross section of the supply cable or 1mm², whichever is higher.
Connect the supply to terminal 91 (neutral) and 90 (life). (See Fig. 17)
TCE8000
Содержание TRICOR TCE80 -E Series
Страница 1: ...Certified according to DIN ISO 9001 Manual TRICOR Coriolis Mass Flow Meter ...
Страница 2: ...SW Version Main V2 0x Display V2 0x Manual Revision 2 1 ...
Страница 90: ...Listings 90 Fig 22 Dimensions TCM5500 C through TCM65k C Fig 23 Dimensions TCM5500 E through TCM65k E ...
Страница 92: ...Listings 92 Remote meter Fig 24 Dimensions TCM A Remote wall mounted electronics Fig 25 Dimensions TCE8000 W ...
Страница 93: ...Listings 93 Fig 26 Dimensions TCE8000 E except A Fig 27 Dimensions TCE8000 E A ...
Страница 98: ...Contact Copyright KEM Subject to change without notice ES Rev 002 23 01 2012 ...