Installation
30
3.1.4 Installation in a Drop Line
The diamond shaped TCM0325 through TCM3100 should not be mounted vertically at all.
All other meters can be mounted vertically, but mounting in a drop line is only allowed, if an orifice and the closing
valve are located below the meter for making sure, that neither during operation nor after closing the valve the
meter will run empty.
Fig. 14: Installation in a Drop Line
3.1.5 Critical
Installations
The meters must not be mounted at the highest point of the tubing, if gas bubbles are to be expected (A), or at the
lowest point, if solid particles are to be expected (B), as in both cases also the right orientation might not help.
Also the meters must not be mounted in a drop line near the open end (C), as in that case the meter might run
empty.
Fig. 15: Critical Installations
Содержание TRICOR TCE80 -E Series
Страница 1: ...Certified according to DIN ISO 9001 Manual TRICOR Coriolis Mass Flow Meter ...
Страница 2: ...SW Version Main V2 0x Display V2 0x Manual Revision 2 1 ...
Страница 90: ...Listings 90 Fig 22 Dimensions TCM5500 C through TCM65k C Fig 23 Dimensions TCM5500 E through TCM65k E ...
Страница 92: ...Listings 92 Remote meter Fig 24 Dimensions TCM A Remote wall mounted electronics Fig 25 Dimensions TCE8000 W ...
Страница 93: ...Listings 93 Fig 26 Dimensions TCE8000 E except A Fig 27 Dimensions TCE8000 E A ...
Страница 98: ...Contact Copyright KEM Subject to change without notice ES Rev 002 23 01 2012 ...