Installation
33
3.2.1 Connecting TCE and TCM
With the remote version the TCE and TCM must be connected before making the other electrical installations. If
no TCM is connected to the TCE, the TCE will only show an error message after power on.
Connecting the cable to the TCM
Open the junction box of the TCM.
Feed the cable from the TCE into the cable gland of the TCM and connect the single wires as described in Tab. 1.
Adjust the position of the cable in the cable glands and close the cable gland.
Terminal Signal Color
1 Driver
+
Grey
2 Driver
-
Pink
3
Sensor A +
Blue
4
Sensor A -
Red
5
Sensor B +
White
6
Sensor B -
Brown
7 Pt1000
+
Green
8 Pt1000
-
Yellow
PE
Protective ground
Yellow / green
Tab. 1: Connections TCMxxxx
Close the top cover of the junction box and fix it with the screw.
Connecting the cable to the TCE80**-L-* or TCE80**-W-*
Put the D-Sub connector of the cable to the connector “sensor” on the back side of the housing.
Connecting the cable to the TCE80**-E-***A-Ex
With the TCE80**-E-***A-Ex the cable is not fixed to the TCE and must be connected separately.
Open the junction box of the TCE.
Feed the cable from the TCM into the cable gland of the TCE junction box.
Push the cable end sleeves into the terminals according to tab. Tab. 1. There is no tool required to connect the
cables.
If cables without end sleeves are to be connected or if cables have to be removed, open the terminal by pressing
a small screwdriver into the orange operator of the terminal.
Adjust the position of the cable in the cable glands and close the cable gland.
Close the top cover of the junction box and fix it with the screw.
3.2.2 Electrical Installation of Wall Mount and Compact Version
Connect the TCM to the TCE (see chapter 3.2.1, remote version only)
Open the safety screw at the display cover of the unit with the provided Allen key.
Remove the display cover of the TCE by turning it counter clockwise.
Pull out the display
Prepare the cable for installation:
Separate the single wires for about 12 cm
Strip the end and cover it with a cable end sleeve
Connect a 7 cm long stranded wire to the shield
Feed the cable through the cable gland.
Connect the shield to the PE screw.
Содержание TRICOR TCE80 -E Series
Страница 1: ...Certified according to DIN ISO 9001 Manual TRICOR Coriolis Mass Flow Meter ...
Страница 2: ...SW Version Main V2 0x Display V2 0x Manual Revision 2 1 ...
Страница 90: ...Listings 90 Fig 22 Dimensions TCM5500 C through TCM65k C Fig 23 Dimensions TCM5500 E through TCM65k E ...
Страница 92: ...Listings 92 Remote meter Fig 24 Dimensions TCM A Remote wall mounted electronics Fig 25 Dimensions TCE8000 W ...
Страница 93: ...Listings 93 Fig 26 Dimensions TCE8000 E except A Fig 27 Dimensions TCE8000 E A ...
Страница 98: ...Contact Copyright KEM Subject to change without notice ES Rev 002 23 01 2012 ...