Indoor unit installation  9

Indoor unit installation

Recommended circuit breaker rating

Model

Circut breaker rating (Amps)

KSV25CRG, KSV25HRG, 
KSD25HRG

15A

KSV35CRG, KSV35HRG, 
KSD35HRG

15A

KSV50HRG, KSD50HRG

20A

KSV70CRG, KSV70HRG, 
KSD70HRG

25A

KSV80HRG, KSD80HRG

25A

NOTE: The wire size of power supply cord and interconnected 

wire and the current of the fuse or switch are determined by the 

maximum current indicated on the nameplate which located on 

the side panel of the unit. Please refer to the nameplate before 

selecting the wire size, fuse or switch.

TIPS & INFORMATION

 important

Take note of fuse specifications

The air conditioners circuit board (PCB) is designed with a fuse to 
provide over current protection. The specifications of the fuse are 
printed on the circuit board, such as:

Indoor unit:

 T3.15A/250VAC, T5A/250VAC (applicable for unit 

adopts R32 refrigerant).

Outdoor unit:

 T20A/250VAC (for < 5.0kW unit), T30A/250VAC  

(for >  5.0kW unit)

NOTE: The fuse is made of ceramic.

Connect the cable to the indoor unit

NOTE: Before performing any electrical work, turn off the main 

power to the system.

1.   Use suitably rated power cable to connect to the indoor unit. 

Note the main power supply goes to the outdoor unit and the 
indoor unit does not carry full compressor current, therefore 
1mm

2

 (or larger) wire is suitable for connecting between indoor 

unit and outdoor unit accordingly.

2.   Lift the indoor unit panel up, remove the wire box cover by 

loosening the screw.

3.   Feed in the active, neutral, earth and signal wires from the 

outside until the wires are visible in the indoor unit terminal 
block area.

4.   Remove the cable clamp. Match wire colours with terminal 

numbers on indoor and outdoor unit terminal blocks and firmly 
screw wires to the corresponding terminals. It is recommended 
to use the following wire colour sequence:  
1(L) = Brown;  
2(N) = Blue;  
S = White;  
(Earth) = Yellow & Green.

5.   Connect the end of the connection cable fully inserting into 

the terminal block. Tighten the terminal block screws, then 
gently pull on the wires to confirm they are securely attached.

6.   Fasten the connection cable with a cable clamp.

7.   Re-fit the wire box cover and secure with the screw, then close 

the indoor unit cover.

Terminal block

Terminal block

active 

brown

neutral

blue

1(L) 2(N) S

signal

white

earth (yellow

and green)

Wire cover

Screw

Screw

Cable clamp

Fig 7.

1.   Use vinyl tape to tape the power cables to the drain pipe and 

hose assembly with drain hose at the bottom. 

2.   Carefully pass the piping and wiring assembly through the 

hole, taking care to ensure that no pipe or cable touches any 
sharp edge within the cut wall.

3.   Hook the indoor unit onto the upper portion of installation 

plate (Engage the indoor unit with the upper edge of the 
installation plate). Ensure the hooks are properly seated on the 
installation plate by moving it in left and right.

4.   Piping can easily be made by lifting the indoor unit with a 

cushioning material between the indoor unit and the wall.  
Get it out after finish piping. When use a wall embedded pipe, 
the indoor unit can be moved to the left or right for 30–50mm 
(model dependent), which offers sufficient space to arrange 
the pipes and ensure the indoor unit fully close to the wall  
after installation.

5.   Press the lower left and right side of the unit against the 

installation plate until hooks engages with the their slots.

Fig 8.

Upper hook

Lower hook

Cushioning

material

Wall embedded 

pipe

Move to left or right

30°

150mm

30-50mm

30-50mm

Содержание KSV25CRG

Страница 1: ...Inverter Air Conditioner Installation Manual KSV25CRG KSV35CRG KSV70CRG KSV25HRG KSD25HRG KSV35HRG KSD35HRG KSV50HRG KSD50HRG KSV70HRG KSD70HRG KSV80HRG KSD80HRG...

Страница 2: ...air conditioner is designed for and intended to be used in normal domestic applications only Record model and serial number here Model number Serial number ENVIRONMENTAL TIPS environment Information...

Страница 3: ...esponsible for their safety Children should be supervised to ensure that they do not play with the appliance WARNING warning Before obtaining access to terminals all supply circuits must be disconnect...

Страница 4: ...inimum room sizes are adhered to for standard installations up to 5m pipe length If larger refrigerant charges than standard are used then please consult AS NZS 60335 2 40 to determine the safe minimu...

Страница 5: ...l Before screwing the remote controller holder to the wall make sure that control signals are properly received by indoor unit 2x AAA batteries In sites with poor drainage use block bases for outdoor...

Страница 6: ...appropriate wall fixings suitable for the wall type being fixed to which is sufficient to support the full weight of the indoor unit 3 Secure the installation plate to the wall with screws NOTE Mount...

Страница 7: ...to drain from both sides another drain pipe will need to be supplied by the installer If choosing one side drainage connection make sure the drain hole on the other side is well plugged For 2 5kW 3 5k...

Страница 8: ...shall be installed in accordance with national wiring regulations 5 An all pole disconnection device which has at least 3mm clearances in all poles the residual current device RCD having a rated resi...

Страница 9: ...lamp Match wire colours with terminal numbers on indoor and outdoor unit terminal blocks and firmly screw wires to the corresponding terminals It is recommended to use the following wire colour sequen...

Страница 10: ...or the outdoor unit with a 8 or 10 diameter bolt and nut tightly and horizontally on a concrete or rigid mount Model Outdoor unit dimensions W x H x D mm Outdoor unit weight kg Dimensions A mm Dimensi...

Страница 11: ...ich also indicates the maximum pipe length and maximum height difference between indoor and outdoor units Please also refer to the below table for discharge and suction pipe diameter Model Discharge p...

Страница 12: ...longer than the pipe length 5 Cut pipes must follow the requirements shown in figure 12 Burr removal 1 Completely remove all burrs from the cut cross section of the pipe 2 Put the end of the copper pi...

Страница 13: ...ally plug the hole in the wall using gum type sealer Indoor unit tubing Flare nut Pipings Fig 16 Fig 17 Outdoor unit electrical connection 1 Check that power supply to the air conditioner circuit is o...

Страница 14: ...lick is heard to confirm it has locked into place Secure the demand response cable in the cable clamp then fit the terminal block cover and secure with screws Outdoor unit installation Magnetic ring i...

Страница 15: ...mum height m Additional refrigerant g m KSV25CRG 6 35 1 4 9 52 3 8 5 25 10 15 KSV35CRG 6 35 1 4 12 7 1 2 5 25 10 15 KSV70CRG 9 52 3 8 15 9 5 8 5 50 25 30 KSV25HRG 6 35 1 4 9 52 3 8 5 25 10 15 KSV35HRG...

Страница 16: ...as pipe side and check that the air is entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus Then retighten the flare nut 5 Keep the vacuum pump running...

Страница 17: ...over Outdoor unit check point B D C A Fig 22 Operation test After confirming the electrical safety has passed and confirmed there are no gas leaks follow the below steps to complete an operation test...

Страница 18: ...isks NO SMOKING signs shall be displayed Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of...

Страница 19: ...le for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need re calibration Detection e...

Страница 20: ...e dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant Recovery When removing refrigerant from a system either for servicing or decommiss...

Страница 21: ...Kelvinator Air Conditioning Notes 21 Notes...

Страница 22: ...22 Notes Kelvinator Air Conditioning Notes...

Страница 23: ...y unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii...

Страница 24: ...r appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web kelvinator com au Ke...

Отзывы: