Congratulations and thank you for choosing our Inverter split 
system room air conditioner. We are sure you will find  
your new air conditioner a pleasure to use. Before you use the air 
conditioner, we recommend that you read through  
the entire user manual, which provides the description of  
the air conditioner and its functions.

To avoid the risks that are always present when you use an electrical 
appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.

We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.

After unpacking the air conditioner please check it is not damaged. 
If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

Conditions of use

This appliance is intended to be used in household and similar 
applications such as :

•    

staff kitchen areas in shops, offices and other working 
environments.

•    

farm houses.

•    

by clients in hotels, motels and other residential type 
environments.

•    

bed and breakfast type environments.

This air conditioner is designed for and intended to be used in 
normal domestic applications only.

Record model and serial number here:

 

Model number: 

 ..................................................................................

 

Serial number: 

 ...................................................................................

ENVIRONMENTAL TIPS

 environment

Information on disposal for users
•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 

recycling depot or by placing them in appropriate collection 

containers.

•    If you wish to discard this air conditioner, please contact your 

local authorities and ask for the correct method  

of disposal.

R300 refrigerant warning

R32 refrigerant warning

This product uses R32 difluoromethane refrigerant, which is 

a mildly flammable gas class 2.2 according according to AS 

1677 and must be handled by a refrigeration mechanic with 

appropriate Australian refrigerant handling licence.

Congratulations

Contents

2  Contents 

Kelvinator Air Conditioning

Important Safety Instructions

 ................................................. 3

Installation instructions

Choosing a location to mount unit ............................................... 4
Installation drawing ......................................................................... 5

Indoor unit installation

Installation plate mounting ............................................................ 6
Drilling the wall ................................................................................ 7
Connective pipe installation .......................................................... 7
Drain piping ..................................................................................... 8

Outdoor unit installation

Location of outdoor unit .............................................................. 10
Drain elbow installation ................................................................ 10
Refrigerant pipe connection ........................................................ 11
Flaring work ................................................................................... 12

Test running

Air purging ..................................................................................... 15

Information servicing

Information servicing .................................................................... 18

Warranty

 ...................................................................................... 23

Содержание KSV25CRG

Страница 1: ...Inverter Air Conditioner Installation Manual KSV25CRG KSV35CRG KSV70CRG KSV25HRG KSD25HRG KSV35HRG KSD35HRG KSV50HRG KSD50HRG KSV70HRG KSD70HRG KSV80HRG KSD80HRG...

Страница 2: ...air conditioner is designed for and intended to be used in normal domestic applications only Record model and serial number here Model number Serial number ENVIRONMENTAL TIPS environment Information...

Страница 3: ...esponsible for their safety Children should be supervised to ensure that they do not play with the appliance WARNING warning Before obtaining access to terminals all supply circuits must be disconnect...

Страница 4: ...inimum room sizes are adhered to for standard installations up to 5m pipe length If larger refrigerant charges than standard are used then please consult AS NZS 60335 2 40 to determine the safe minimu...

Страница 5: ...l Before screwing the remote controller holder to the wall make sure that control signals are properly received by indoor unit 2x AAA batteries In sites with poor drainage use block bases for outdoor...

Страница 6: ...appropriate wall fixings suitable for the wall type being fixed to which is sufficient to support the full weight of the indoor unit 3 Secure the installation plate to the wall with screws NOTE Mount...

Страница 7: ...to drain from both sides another drain pipe will need to be supplied by the installer If choosing one side drainage connection make sure the drain hole on the other side is well plugged For 2 5kW 3 5k...

Страница 8: ...shall be installed in accordance with national wiring regulations 5 An all pole disconnection device which has at least 3mm clearances in all poles the residual current device RCD having a rated resi...

Страница 9: ...lamp Match wire colours with terminal numbers on indoor and outdoor unit terminal blocks and firmly screw wires to the corresponding terminals It is recommended to use the following wire colour sequen...

Страница 10: ...or the outdoor unit with a 8 or 10 diameter bolt and nut tightly and horizontally on a concrete or rigid mount Model Outdoor unit dimensions W x H x D mm Outdoor unit weight kg Dimensions A mm Dimensi...

Страница 11: ...ich also indicates the maximum pipe length and maximum height difference between indoor and outdoor units Please also refer to the below table for discharge and suction pipe diameter Model Discharge p...

Страница 12: ...longer than the pipe length 5 Cut pipes must follow the requirements shown in figure 12 Burr removal 1 Completely remove all burrs from the cut cross section of the pipe 2 Put the end of the copper pi...

Страница 13: ...ally plug the hole in the wall using gum type sealer Indoor unit tubing Flare nut Pipings Fig 16 Fig 17 Outdoor unit electrical connection 1 Check that power supply to the air conditioner circuit is o...

Страница 14: ...lick is heard to confirm it has locked into place Secure the demand response cable in the cable clamp then fit the terminal block cover and secure with screws Outdoor unit installation Magnetic ring i...

Страница 15: ...mum height m Additional refrigerant g m KSV25CRG 6 35 1 4 9 52 3 8 5 25 10 15 KSV35CRG 6 35 1 4 12 7 1 2 5 25 10 15 KSV70CRG 9 52 3 8 15 9 5 8 5 50 25 30 KSV25HRG 6 35 1 4 9 52 3 8 5 25 10 15 KSV35HRG...

Страница 16: ...as pipe side and check that the air is entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus Then retighten the flare nut 5 Keep the vacuum pump running...

Страница 17: ...over Outdoor unit check point B D C A Fig 22 Operation test After confirming the electrical safety has passed and confirmed there are no gas leaks follow the below steps to complete an operation test...

Страница 18: ...isks NO SMOKING signs shall be displayed Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of...

Страница 19: ...le for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need re calibration Detection e...

Страница 20: ...e dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant Recovery When removing refrigerant from a system either for servicing or decommiss...

Страница 21: ...Kelvinator Air Conditioning Notes 21 Notes...

Страница 22: ...22 Notes Kelvinator Air Conditioning Notes...

Страница 23: ...y unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii...

Страница 24: ...r appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web kelvinator com au Ke...

Отзывы: