6 Indoor unit installation
Kelvinator Air Conditioning
Indoor unit installation
Remove the installation plate from the indoor unit. The installation
plate should be installed on a wall which can support the weight of
the indoor unit.
Model
Indoor unit
dimensions
W x H x D (mm)
Weight (kg)
KSV25CRG
KSV25HRG
KSD25HRG
KSV35CRG
KSV35HRG
KSD35HRG
802 x 297 x 189
10
KSV50HRG
KSD50HRG
KSV70CRG
KSV70HRG
KSD70HRG
KSV80HRG
KSD80HRG
1080 x 335 x 226
15
Installation plate mounting
1. Fit the installation plate horizontally on structural parts of
the wall with sufficient space around the installation plate
to accommodate the indoor unit and meet the clearance
requirements as per the assembly diagram, see figure 1.
2. Use appropriate wall fixings suitable for the wall type being
fixed to which is sufficient to support the full weight of the
indoor unit.
3. Secure the installation plate to the wall with screws.
NOTE: Mount the installation plate and drill holes in the wall
according to the wall structure and corresponding mounting points
on the installation plate. The installation plate provided with the
machine differ from appliance to appliance. (Dimensions are in mm
unless otherwise stated).
Correct orientation
of Installation Plate
✗
✓
✗
232
219
581
300
53.5
76
53.5
335
232
128
192
KSV25CRG, KSV25HRG, KSD25HRG,
KSV35CRG, KSV35HRG, KSD35HRG
KSV50HRG, KSD50HRG, KSV70CRG,
KSV70HRG, KSD70HRG, KSV80HRG,
KSD80HRG
802
1080
297
43
43
43
65
75
65
75
Left rear side
refrigerant
pipe hole
Left rear side
refrigerant
pipe hole
Right rear side
refrigerant
pipe hole
Right rear side
refrigerant
pipe hole
Indoor unit
outline
Indoor unit
outline