14 Outdoor unit installation
Kelvinator Air Conditioning
Electrical connection
Wiring diagram
1(L)
1(L)
2(N)
2(N)
S
S
L
N
Indoor unit terminal block
(3)
Power supply
Outdoor unit terminal block
Key:
1(L) = Live (Brown)
2(N) = Neutral (Blue)
S = Signal (White)
= Earth (Yellow & Green)
Installation of DRED network cable
The following models are equipped with a RJ45 Demand Response
connection socket to facilitate demand response control by your
electricity provider:
KSD25HRG, KSD35HRG, KSD50HRG, KSD70HRG, KSD80HRG
Please refer to your electricity provider for more information about
DRED.
The DRED socket is located inside the outdoor unit near the
terminal block, and is labelled "DR", refer to figure 19.
Connect the demand response cable into the DRED socket labelled
DR, ensure that a click is heard to confirm it has locked into place.
Secure the demand response cable in the cable clamp, then fit the
terminal block cover and secure with screws.
Outdoor unit installation
Magnetic ring installation
Please note that the following models are supplied with two
additional magnetic rings: KSV50HRG, KSD50HRG
These magnetic rings must be installed in the outdoor unit terminal
block area with one ring clipped around the main power supply into
the outdoor unit (around Active, Neutral and Earth wires), and the
second ring is clipped around the interconnecting wires leading to
the indoor unit (around Active, Neutral, Earth and Signal wires). The
rings should be located approximately 4cm away from the outdoor
unit terminal block, and secured in place with cable ties or vinyl
tape. After fitting the magnetic rings, refit the cover and secure in
place with the screw. Refer the figure 19 showing where to fit the
magnetic rings.
Fig. 19
1(L)
DR
40mm
2(N)
S
L
N
Содержание KSV25CRG
Страница 21: ...Kelvinator Air Conditioning Notes 21 Notes...
Страница 22: ...22 Notes Kelvinator Air Conditioning Notes...