Installation 

C2N Series Tankless Heater

Bradley • 

215-1821 Rev. B; ECN 16-17-005 

5/3/2016

Plumbing Installation

2

C

Use 3/4" hard copper tubing or pipe as needed . 

A

Install shutoff valve above (upstream of) the heater . 
inlet

NOTICE!  Failure to install proper filtration may 

result in a flow switch malfunction.

NOTICE!  To avoid water damage, install a drain 

pipe from the pressure relief valve to 
an unrestricted drain.

If end use fixture is not at the highest point in 
the plumbing loop, then an automatic air vent 
valve must be added at the highest point in the 
system or at any drop to eliminate trapped air.

Components Needed:

•  (2) Union 3/4"
•  Shutoff Valve
•  Pressure and Temperature Relief Valve (150 psi/10 bar)
•  Y-Strainer (100 mesh) or Inline Filter (150 microns)
•  (2) Gate or Ball Type Valves
•  Drain pipe
•  Water hammer arrestor (recommended)
•  Elbows, nipples and fittings as needed

Dim. "A"

Dim. "B"

36kW

31-1/2" (800)

30" (762)

50kW

37-1/2" (953)

36" (914)

Dimensions, Plumbing and 
Electrical Configurations

2" 

(51)

3/4" Female 

NPT Inlet

3/4" 

Female 

NPT Outlet

10" 

(254)

A

22-1/2" (572)

24" (610)

B

3-3/8" 

(86)

8" 

(203)

8-3/4" 

(222)

Optional Fused 

Disconnect

Suggested 

Location for 

Power  Entrance  

- Provided By 

Installer

LOAD L

LOAD R

READY

TEST

FAULT

RESET

GROUND FAULT

TEMPERATURE CONTROLLER

R

1
2
3
4
5

Outlet

To Drain

Inlet

P&T Relief 

Valve

Threaded 

Unions

Y-Strainer 

Recommended

Suggested Installation Configuration

Components provided by installer unless 

otherwise specified . Reference the product 

options sections or contact your local 

Bradley Representative for product options .

Ball Valves

B

Install one union on the water inlet side of the 
heater . Install one 100 Mesh (150 micron) Y-strainer 
above (upstream of) union .
Install one union on the water outlet side of the heater . 
Install one P & T Relief Valve above (downstream of)
union .
Install the pressure relief valve (150 psi/10 bar) and 
outlet plumbing of heater per code requirements and 
route relief valve discharge to drain . Make sure no 
shutoff valve is between the water heater outlet and 
the relief valve, as well as no shutoff valve between 
the relief valve discharge and drain . Install hammer 
arrestor . Ensure plumbing is secure and not subject 
to vibrations .

CAUTION  To avoid damage to the electronics 

or internal wiring, do not perform any 
brazing or sweat soldering inside the 
enclosure.

Содержание C2N363/600D

Страница 1: ...s C2N36 C2N50 Voltage options 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instructions 3 Mounting Heater 4 Plumbing Inst...

Страница 2: ...result in serious burns or death Disconnect power supply before performing any work in the enclosure Failure to ground this system may result in death or serious injury Make sure that all water supply...

Страница 3: ...ing quick close valves or solenoid valves it is important to install a hammer arrestor or surge tank close to the point of use to absorb pressure spikes Installation Considerations Maximum operating p...

Страница 4: ...the vertical surface Vertical surface must support 150 lbs or more Optional Leg Kit Use the floor mounting template on the side of the crate to help with alignment Secure heater by bolting each leg t...

Страница 5: ...0 B 3 3 8 86 8 203 8 3 4 222 Optional Fused Disconnect Suggested Location for Power Entrance Provided By Installer LOAD L LOAD R READY TEST FAULT RESET GROUND FAULT TEMPERATURE CONTROLLER R 1 2 3 4 5...

Страница 6: ...tranded machine tool wire from an approved isolating 3 pole switch or circuit breaker NOTICE Make sure the electrical cable is the correct size to carry 100 of the full load current See table for prop...

Страница 7: ...f valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point...

Страница 8: ...activate the connected process requiring heated water faucet shower etc then flush the system for 5 minutes to ensure all air is purged from the system NOTICE Failure to bleed air properly will damage...

Страница 9: ...output temperature Setpoint Down Button Decreases output temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off X...

Страница 10: ...lements if the inlet water temperature is equal to or greater than the temperature set on the digital controller Perform Operational Test No 2 8 A Turn on hot water faucet fixture process The heater s...

Страница 11: ...used disconnect interlocks with enclosure door when energized prohibiting access to a live cabinet Select the FDS option for an additional level of safety and convenience at the heater location T190 H...

Страница 12: ...ery 6 months or more often in areas where hard water sediment is present in the water To clean the Y Strainer 1 Turn the power off at the circuit breaker panel 2 Shut off the installer supplied cold w...

Страница 13: ...al Specifications table in Step 3 for proper requirements 2 Unit is receiving voltage from all 3 phases of the power source A load voltage reading is also helpful 3 Verify the functionality of the flo...

Страница 14: ...Purge gas compressed air inlet fitting here EXP2 Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ratings 2 A...

Страница 15: ...osure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 16: ...irements No valves may be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas fr...

Страница 17: ...larms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: