Installation 

C2N Series Tankless Heater

Bradley • 

215-1821 Rev. B; ECN 16-17-005 

5/3/2016

Pre-Installation Information

General Information

The Keltech Tankless Water Heater provides instant and precise temperature-controlled hot water . To insure proper 
performance, install the heater according to the following installation instructions and in compliance with applicable 
national and local codes .

Keltech can supply heaters for most commercial and industrial hot water applications . Flow rates and temperature 
figures are important for proper sizing . If needed to meet certain temperature demands, flow control devices are 
readily available . See Temperature Rise Specifications Chart . Contact 

KELTECH, INC.

 for further information on 

available flow control devices . 

Operation and Setup

C2N Series heaters supply an unlimited amount of hot water with specific flow and temperature rise capabilities . 
These heaters are energy efficient, reliable, and provide optimum performance in the most demanding applications . 

Application Specific Requirements

The C2N Series can be used in many different applications that require custom tuning for specific applications to 
maximize performance of the heater .
For use in a recirculation loop, the incoming loop temperature should not exceed 140°F (60°C) .
For applications utilizing quick close valves or solenoid valves, it is important to install a hammer arrestor or surge 
tank close to the point of use to absorb pressure spikes .

Installation Considerations

Maximum operating pressure: 150 psi (10 bar) 
Standard flow activation: 0 .75 gpm (2 .8 lpm)

Certifications

Keltech Electric Tankless Water Heaters are certified by ETL to UL499, UL50E, CSA22 .2 No 88 and NFPA 496 
(for hazardous locations) and third party certified to NSF/ANSI 372 . Heaters are compliant to NEC/NFPA 70 and 
Canadian Electrical Code C22 .1 .

WARNING For safe operation of the heater, observe all the warning labels as indicated.

Storage Instructions

NOTICE! Keep Keltech Electric Tankless Water Heaters stored in original packaging until installation.  

Recommended storage criteria: 

Store Keltech Electric Tankless Water Heaters where temperatures exceed 35°F (2°C) at all times .
Indoor storage is recommended .
Minimize excessive on-site transport to reduce risk of shock and impact damage . 

Alternate storage: 

If in the original crate, Keltech Electric Tankless Water Heaters will withstand outside storage for approximately 1 
month in most climates . Crate may not be capable of protecting the heater if left outside longer than this time frame .
If the Keltech Electric Tankless Water Heater is stored in an outdoor environment, care should be taken to protect the 
heaters from:

•  Rain or other falling precipitation via tarp or other waterproof media .
•  Runoff and accumulation of groundwater from any source that may exceed 1 inch (25mm) .

Содержание C2N363/600D

Страница 1: ...s C2N36 C2N50 Voltage options 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instructions 3 Mounting Heater 4 Plumbing Inst...

Страница 2: ...result in serious burns or death Disconnect power supply before performing any work in the enclosure Failure to ground this system may result in death or serious injury Make sure that all water supply...

Страница 3: ...ing quick close valves or solenoid valves it is important to install a hammer arrestor or surge tank close to the point of use to absorb pressure spikes Installation Considerations Maximum operating p...

Страница 4: ...the vertical surface Vertical surface must support 150 lbs or more Optional Leg Kit Use the floor mounting template on the side of the crate to help with alignment Secure heater by bolting each leg t...

Страница 5: ...0 B 3 3 8 86 8 203 8 3 4 222 Optional Fused Disconnect Suggested Location for Power Entrance Provided By Installer LOAD L LOAD R READY TEST FAULT RESET GROUND FAULT TEMPERATURE CONTROLLER R 1 2 3 4 5...

Страница 6: ...tranded machine tool wire from an approved isolating 3 pole switch or circuit breaker NOTICE Make sure the electrical cable is the correct size to carry 100 of the full load current See table for prop...

Страница 7: ...f valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point...

Страница 8: ...activate the connected process requiring heated water faucet shower etc then flush the system for 5 minutes to ensure all air is purged from the system NOTICE Failure to bleed air properly will damage...

Страница 9: ...output temperature Setpoint Down Button Decreases output temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off X...

Страница 10: ...lements if the inlet water temperature is equal to or greater than the temperature set on the digital controller Perform Operational Test No 2 8 A Turn on hot water faucet fixture process The heater s...

Страница 11: ...used disconnect interlocks with enclosure door when energized prohibiting access to a live cabinet Select the FDS option for an additional level of safety and convenience at the heater location T190 H...

Страница 12: ...ery 6 months or more often in areas where hard water sediment is present in the water To clean the Y Strainer 1 Turn the power off at the circuit breaker panel 2 Shut off the installer supplied cold w...

Страница 13: ...al Specifications table in Step 3 for proper requirements 2 Unit is receiving voltage from all 3 phases of the power source A load voltage reading is also helpful 3 Verify the functionality of the flo...

Страница 14: ...Purge gas compressed air inlet fitting here EXP2 Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ratings 2 A...

Страница 15: ...osure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 16: ...irements No valves may be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas fr...

Страница 17: ...larms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: