C2N Series Tankless Heater

 Installation

5/3/2016 

Bradley • 

215-1821 Rev. B; ECN 16-17-005

Maintenance 

Preventative maintenance is important for optimal performance of the heater . To ensure the heater works properly, 
always keep the inside of the enclosure dry . Moisture inside an enclosure increases the humidity, which condenses 
on cooler surfaces . This can cause electrical problems and reduce the efficiency of enclosure insulation . To prevent 
problems perform the following:
•  Verify the interior of the enclosure is dry .

•  Verify there are no leaks in seals of enclosure and that in high humidity environments all enclosure egresses are 

properly sealed .

•  Ensure plugs are in place on back side of enclosure .

•  Check seals monthly during temperatures above 32°F (0°C) and weekly during temperatures below 32°F(0°C) . 

•  Bimetal Manual Reset Safeties are set to trip at 175°F (79°C) . If this temperature is reached, the Bimetal Manual 

Safeties will trip and need to be reset .

•  All heaters require filtration of 150 microns or smaller to ensure proper operation . Y-strainers or additional filtration 

should be verified and cleaned at least every 6 months or more often in areas where hard water sediment is 
present in the water . 
 
To clean the Y-Strainer:

1 .  Turn the power off at the circuit breaker panel . 
2 .  Shut off the installer supplied cold water isolation valve to the heater .
3 .  Relieve pressure in the plumbing lines .
4 .  Position a bucket under the cold water inlet to catch any water that may still be in the pipe .
5 .  Loosen the plumbing connection on the Y-strainer to get to the screen .
6 .  Remove screen and clean out debris . Use a wire brush to clean smaller particles from the screen .
7 .  Once the screen is clean, put it back into the Y-strainer housing and secure the plumbing connection .
8 .  Before switching the power back on, bleed the air out of the lines by turning heater water supply back on and 

the plumbing fixture or process farthest from the heater .

9 .  With the air purged, turn on all circuit breakers supplying the water heater . 

•  At the same time the Y-strainer or additional filtration is cleaned, it is a good practice to also check all valves 

connected to the system . With no water flow through the heater, work both the inlet ball valves and the outlet gate 
valves open and shut to break up any calcium deposits that may have formed from the valve being open for an 
extended period of time . Power to the heater does not need to be turned off to do this .

Содержание C2N363/600D

Страница 1: ...s C2N36 C2N50 Voltage options 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instructions 3 Mounting Heater 4 Plumbing Inst...

Страница 2: ...result in serious burns or death Disconnect power supply before performing any work in the enclosure Failure to ground this system may result in death or serious injury Make sure that all water supply...

Страница 3: ...ing quick close valves or solenoid valves it is important to install a hammer arrestor or surge tank close to the point of use to absorb pressure spikes Installation Considerations Maximum operating p...

Страница 4: ...the vertical surface Vertical surface must support 150 lbs or more Optional Leg Kit Use the floor mounting template on the side of the crate to help with alignment Secure heater by bolting each leg t...

Страница 5: ...0 B 3 3 8 86 8 203 8 3 4 222 Optional Fused Disconnect Suggested Location for Power Entrance Provided By Installer LOAD L LOAD R READY TEST FAULT RESET GROUND FAULT TEMPERATURE CONTROLLER R 1 2 3 4 5...

Страница 6: ...tranded machine tool wire from an approved isolating 3 pole switch or circuit breaker NOTICE Make sure the electrical cable is the correct size to carry 100 of the full load current See table for prop...

Страница 7: ...f valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point...

Страница 8: ...activate the connected process requiring heated water faucet shower etc then flush the system for 5 minutes to ensure all air is purged from the system NOTICE Failure to bleed air properly will damage...

Страница 9: ...output temperature Setpoint Down Button Decreases output temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off X...

Страница 10: ...lements if the inlet water temperature is equal to or greater than the temperature set on the digital controller Perform Operational Test No 2 8 A Turn on hot water faucet fixture process The heater s...

Страница 11: ...used disconnect interlocks with enclosure door when energized prohibiting access to a live cabinet Select the FDS option for an additional level of safety and convenience at the heater location T190 H...

Страница 12: ...ery 6 months or more often in areas where hard water sediment is present in the water To clean the Y Strainer 1 Turn the power off at the circuit breaker panel 2 Shut off the installer supplied cold w...

Страница 13: ...al Specifications table in Step 3 for proper requirements 2 Unit is receiving voltage from all 3 phases of the power source A load voltage reading is also helpful 3 Verify the functionality of the flo...

Страница 14: ...Purge gas compressed air inlet fitting here EXP2 Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ratings 2 A...

Страница 15: ...osure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 16: ...irements No valves may be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas fr...

Страница 17: ...larms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: