Packaging

Crates are constructed from 3/4" (19mm) OSB . 
Crate dimensions approx: 44" x 28" x 12" (1118mm x 711mm x 305mm)
Crates should not be stacked more than 2 high .
All crates must be stacked evenly and horizontally .
Safety issues related to packaging:

•  Product should be transported with the care associated to packages labeled “FRAGILE” even if packaging is not 

marked accordingly .

•  Standard safety procedures for forklift transport and large items less than 1000lbs (454 kgs) should be followed at 

all times . 

•  When stored, crate must be supported in entirety of its length and width .

Mounting Heater

1

WARNING HIGH VOLTAGE SHOCK. Disconnect power supply before performing any work inside 

the heater enclosure.

A

Set heater in a vertical, upright position 
with the water outlet located at top . 

B

Standard Wall Mount 

Mount heater to the wall using the (4) 
mounting brackets on the back of the 
enclosure . Bolt the heater to the vertical 
surface . Vertical surface must support  
150 lbs or more .

Optional Leg Kit 

Use the floor mounting template on the 
side of the crate to help with alignment . 
Secure heater by bolting each leg to the 
floor using 3/8" (10mm) anchor bolts .

C

Install the pressure and temperature relief 
valve on hot water outlet immediately 
following the union .

NOTICE! Valve must empty into a drain.

For best results, install heater as close as possible to the point of use.

Installation should be performed by a qualified plumber or electrician. 

Long pipe runs are not recommended. A heat loss of 1°F for every 10ft (3 meters) of uninsulated 
pipe can occur. 

When determining a mounting location, give consideration to the location of the main electrical panel 
and ensure accessibility of the cabinet enclosure door and other plumbing for service/maintenance. 36" 
(914mm) minimum in front of the cabinet enclosure is required. 

24" 

(609mm)

16¼" 

(413mm)

10¼" 

(260mm)

4" 

(102mm)

4" 

(102mm)

8" 

(203mm)

⁷⁄₁₆

" x ¾"  

(10mm x 20mm) 

Slot  

(6 Places)

Rectangle outlines on template are not 
actual size of heater.

Template may require cutting to fit into 
tight areas.
Holes are for alignment purposes and may 
not represent actual drill size for mounting 
hardware.

Содержание C2N363/600D

Страница 1: ...s C2N36 C2N50 Voltage options 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instructions 3 Mounting Heater 4 Plumbing Inst...

Страница 2: ...result in serious burns or death Disconnect power supply before performing any work in the enclosure Failure to ground this system may result in death or serious injury Make sure that all water supply...

Страница 3: ...ing quick close valves or solenoid valves it is important to install a hammer arrestor or surge tank close to the point of use to absorb pressure spikes Installation Considerations Maximum operating p...

Страница 4: ...the vertical surface Vertical surface must support 150 lbs or more Optional Leg Kit Use the floor mounting template on the side of the crate to help with alignment Secure heater by bolting each leg t...

Страница 5: ...0 B 3 3 8 86 8 203 8 3 4 222 Optional Fused Disconnect Suggested Location for Power Entrance Provided By Installer LOAD L LOAD R READY TEST FAULT RESET GROUND FAULT TEMPERATURE CONTROLLER R 1 2 3 4 5...

Страница 6: ...tranded machine tool wire from an approved isolating 3 pole switch or circuit breaker NOTICE Make sure the electrical cable is the correct size to carry 100 of the full load current See table for prop...

Страница 7: ...f valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point...

Страница 8: ...activate the connected process requiring heated water faucet shower etc then flush the system for 5 minutes to ensure all air is purged from the system NOTICE Failure to bleed air properly will damage...

Страница 9: ...output temperature Setpoint Down Button Decreases output temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off X...

Страница 10: ...lements if the inlet water temperature is equal to or greater than the temperature set on the digital controller Perform Operational Test No 2 8 A Turn on hot water faucet fixture process The heater s...

Страница 11: ...used disconnect interlocks with enclosure door when energized prohibiting access to a live cabinet Select the FDS option for an additional level of safety and convenience at the heater location T190 H...

Страница 12: ...ery 6 months or more often in areas where hard water sediment is present in the water To clean the Y Strainer 1 Turn the power off at the circuit breaker panel 2 Shut off the installer supplied cold w...

Страница 13: ...al Specifications table in Step 3 for proper requirements 2 Unit is receiving voltage from all 3 phases of the power source A load voltage reading is also helpful 3 Verify the functionality of the flo...

Страница 14: ...Purge gas compressed air inlet fitting here EXP2 Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ratings 2 A...

Страница 15: ...osure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 16: ...irements No valves may be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas fr...

Страница 17: ...larms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: