C2N Series Tankless Heater

 Installation

5/3/2016 

Bradley • 

215-1821 Rev. B; ECN 16-17-005

DANGER

Tip over hazard. System can crush you resulting in serious injury or death. Read and follow precautions in this 
installation manual that accompanied the heater for instructions on how to safely transport and anchor heater. 
Do not transport with the heater in the vertical position. This heater is top heavy and should not be placed in 
the vertical potition until the site is prepared to anchor the heater to the wall or the legs to the floor.

WARNING

Read this manual BEFORE using this equipment. Failure to read and follow all safety and user information 
could result in death, serious personal injury, minor burns, property damage, or damage to the equipment. 
Keep this Manual for future reference. Failure to comply with proper installation and maintenance instructions 
could contribute to the heater’s failure.

A qualified plumber or electrician should install and service this system. Install system according to these 
instructions and in compliance with national and local codes.

ASSE standard 1016, 1069 or 1070 listed devices should be used at fixtures to prevent possible injury.  Severe 
bodily injury including scalding, chilling, and/or death may result depending upon system water pressure 
changes and/or supply water temperature changes.

For safe operation of the heater, observe all warning labels as indicated.

Water heater system under pressure. Do not open enclosure while in operation.

These heaters should never be used to provide “anti-scald” or “anti-chill” service.

Hazardous voltage inside enclosure may result in serious burns or death. Disconnect power supply before 
performing any work in the enclosure.

Failure to ground this system may result in death or serious injury.

Make sure that all water supply lines have been flushed and then completely turned off before beginning 
installation. Debris in supply lines can cause valves to malfunction.

CAUTION

Hot pipes! Do not touch. May cause minor burns.

NOTICE

These heaters do not provide protection from supply or outlet pipe freezing.

Consult local building and plumbing codes prior to installation. Should these codes differ from the information 
in the Manual, follow the local codes. Inquire with governing authorities for additional local requirements.

Regular checking and cleaning of the heater’s internal components and check stops is necessary for maximum 
life and proper product function. Periodic inspection and yearly maintenance by a licensed contractor is 
required. Corrosive water conditions, and/or unauthorized adjustments or repairs could render the heater 
ineffective for its intended service.  Frequency of cleaning and inspection depends upon local water 
conditions. For heaters with adjustable output temperatures, check and adjust as needed at initial installation 
and on a quarterly basis.

IMPORTANT

Read this entire installation manual to ensure proper installation. When finished with the installation, file this 
manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances 
is the responsibility of the installer. Product warranties may be found under “Products” on our Web site at 
www.keltech-inc.com.

Separate parts from packaging and make sure all parts are accounted for before discarding any packaging 
material. If any parts are missing, do not begin installation until you obtain the missing parts.

Содержание C2N363/600D

Страница 1: ...s C2N36 C2N50 Voltage options 600V 3 phase 480V 3 phase 415V 3 phase 400V 3 phase 380V 3 phase Table of Contents Pre Installation Information 2 3 Storage Instructions 3 Mounting Heater 4 Plumbing Inst...

Страница 2: ...result in serious burns or death Disconnect power supply before performing any work in the enclosure Failure to ground this system may result in death or serious injury Make sure that all water supply...

Страница 3: ...ing quick close valves or solenoid valves it is important to install a hammer arrestor or surge tank close to the point of use to absorb pressure spikes Installation Considerations Maximum operating p...

Страница 4: ...the vertical surface Vertical surface must support 150 lbs or more Optional Leg Kit Use the floor mounting template on the side of the crate to help with alignment Secure heater by bolting each leg t...

Страница 5: ...0 B 3 3 8 86 8 203 8 3 4 222 Optional Fused Disconnect Suggested Location for Power Entrance Provided By Installer LOAD L LOAD R READY TEST FAULT RESET GROUND FAULT TEMPERATURE CONTROLLER R 1 2 3 4 5...

Страница 6: ...tranded machine tool wire from an approved isolating 3 pole switch or circuit breaker NOTICE Make sure the electrical cable is the correct size to carry 100 of the full load current See table for prop...

Страница 7: ...f valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point...

Страница 8: ...activate the connected process requiring heated water faucet shower etc then flush the system for 5 minutes to ensure all air is purged from the system NOTICE Failure to bleed air properly will damage...

Страница 9: ...output temperature Setpoint Down Button Decreases output temperature Infinity Key Back to Home page Advance Key Advances through parameter prompts Auto Man Off C r71 Turns Control Loop On Manual Off X...

Страница 10: ...lements if the inlet water temperature is equal to or greater than the temperature set on the digital controller Perform Operational Test No 2 8 A Turn on hot water faucet fixture process The heater s...

Страница 11: ...used disconnect interlocks with enclosure door when energized prohibiting access to a live cabinet Select the FDS option for an additional level of safety and convenience at the heater location T190 H...

Страница 12: ...ery 6 months or more often in areas where hard water sediment is present in the water To clean the Y Strainer 1 Turn the power off at the circuit breaker panel 2 Shut off the installer supplied cold w...

Страница 13: ...al Specifications table in Step 3 for proper requirements 2 Unit is receiving voltage from all 3 phases of the power source A load voltage reading is also helpful 3 Verify the functionality of the flo...

Страница 14: ...Purge gas compressed air inlet fitting here EXP2 Installation Notes 1 Any tubing conduit or fittings connected to the Pressurized Enclosure PE must conform to local codes for flammability ratings 2 A...

Страница 15: ...osure and the protective gas supply The alarm actuator shall be mechanical pneumatic or electrical Electrical alarms and electrical alarm actuators shall be approved for the location in which they are...

Страница 16: ...irements No valves may be fitted between the Expo Technologies system and the alarm switch WARNING Never turn on the power without purging first unless you have proved the interior of the PE is gas fr...

Страница 17: ...larms function correctly Check the Relief Valve and any other Spark Arrestors Remove any debris or corrosion or replace the Spark Arrestor Check the condition of the air supply filter element Clean or...

Отзывы: