
Nanovoltmeter features
The Model 2182 is a 7
1
⁄
2
-digit high-performance digital nanovoltmeter. It has two input
channels to measure voltage and temperature. The measurement capabilities of the Model 2182
are explained in
).
Features of the Model 2182 Nanovoltmeter include:
•
Ratio
— Provides comparison readings between two voltage inputs. Ratio performs
V1/V2.
•
Delta
— Provides average difference of Channel 1 inputs. Delta performs
(V1t1–V1t2)/2.
•
Enhanced Delta, Pulse Delta, and Differential Conductance
— The following tests
can be performed when using a Model 2182/2182A with a Model 6220 or 6221 Current
Source:
—
Delta
- Uses a square wave output and a 3-point measurement algorithm to cancel
the effects of thermal EMFs.
—
Pulse Delta (6221 and 2182A only)
- Provides a pulse output and a 3-point (or
2-point) measurement algorithm for testing of temperature sensitive Device Under
Test (DUT).
—
Differential Conductance
- Uses a differential current output and a 3-point moving
average algorithm to perform differential measurements.
•
mX+b and Percent
— These calculations provide mathematical manipulation of
readings.
•
Relative
— Null offsets or establish baseline values.
•
Buffer
— Store up to 1024 readings in the internal buffer.
•
Limits
— Set high and low reading limits to test devices.
•
Internal Scanning
— Scan the two input channels of the Model 2182.
•
External Scanning
— Scan the channels or matrix points of Keithley Model 7001/7002
switching cards.
•
Setup Storage
— Two instrument setups (user and factory defaults) can be saved and
recalled.
•
Analog Output
— With analog output gain set to one, a full range input will result in a
1V analog output.
•
Remote Interface
— The Model 2182 can be controlled using the IEEE-488 interface
(GPIB) or the RS-232 interface.
•
GPIB Programming Language
— When using the GPIB, the instrument can be
programmed using the SCPI or Model 182 (DDCs) programming language.
•
Closed-cover Calibration
— The Model 2182 can be calibrated from either the front
panel or the GPIB.
1-6
Getting Started
Содержание 2182
Страница 1: ...www tek com keithley Model 2182 2182A Nanovoltmeter User s Manual 2182A 900 01 Rev B May 2017...
Страница 18: ......
Страница 22: ......
Страница 23: ...1 Getting Started Getting Started...
Страница 41: ...2 VoltageandTemperature Measurements Voltageand Temperature Measurements...
Страница 68: ...2 28 Voltage and Temperature Measurements...
Страница 69: ...3 Range Digits Rate andFilter Range Digits Rate andFilter...
Страница 82: ...3 14 Range Digits Rate and Filter...
Страница 83: ...4 Relative mX b and Percent Relative mX b andPercent...
Страница 91: ...5 RatioandDelta Ratioand Delta...
Страница 117: ...6 Buffer Buffer...
Страница 123: ...7 Triggering Triggering...
Страница 140: ...7 18 Triggering...
Страница 141: ...8 Limits Limits...
Страница 149: ...9 SteppingandScanning Steppingand Scanning...
Страница 168: ...9 20 Stepping and Scanning...
Страница 169: ...10 AnalogOutput Analog Output...
Страница 175: ...11 RemoteOperation Remote Operation...
Страница 205: ...12 CommonCommands Common Commands...
Страница 221: ...13 SCPISignalOriented Measurement Commands SCPISignalOri entedMeasure ment Commands...
Страница 225: ...14 SCPIReferenceTables SCPIRefer enceTables...
Страница 239: ...15 AdditionalSCPI Commands Additional SCPICom mands...
Страница 260: ...15 22 Additional SCPI Commands...
Страница 261: ...A Specifications Specifications...
Страница 263: ...B Statusand ErrorMessages StatusandError Messages...
Страница 268: ...B 6 Status and Error Messages...
Страница 269: ...C Measurement Considerations Measurement Consider ations...
Страница 278: ...C 10 Measurement Considerations...
Страница 279: ...D Model182Emulation Commands Model182 EmulationCom mands...
Страница 284: ...D 6 Model 182 Emulation Commands...
Страница 285: ...E Example Programs ExamplePro grams...
Страница 293: ...F IEEE 488 BusOverview IEEE 488Bus Overview...
Страница 307: ...G IEEE 488andSCPI ConformanceInformation IEEE 488and SCPIConform anceInforma tion...
Страница 310: ...G 4 IEEE 488 and SCPI Conformance Information...
Страница 311: ...H Measurement Queries Measurement Queries...
Страница 316: ...H 6 Measurement Queries...
Страница 317: ...I Delta PulseDelta and DifferentialConductance Delta Pulse Deltaand Dif ferentialCon ductance...