background image

INSTALLATION MANUAL 

– check location 

Slim Jim Installation manual 

 

page 6 

Water supply 

 
Rated pressure: 

0.1-0.5 MPa (1-5 bar) 

Rated flow: 

 

minimum 4 litre/minute 

 

The water supply should be able to deliver a minimum amount of 4 litres per minute in the range 0.1-
0.5 MPa (1-5 bar). The machine and accompanying rotary vane pump must be connected with the 
supplied new set of high-pressure hoses (two hoses, each 1.5 meter long), old hose-sets should not 
be re-used. The distance between water treatment system and pump and the distance between pump 
and machine cannot be greater than 1.5 meter unless there is appropriate material available to 
increase these distances.  

Notes! 

Not included in the shipment are supplies to make the connection between the water-tap and the 
water treatment system. 
National rules/regulations may apply when the appliance is connected to the water mains. 

Water treatment system 

The water treatment system should also be able to deliver a minimum amount of 4 litres per minute 
and should at least have a carbon block that not only traps drug-remnants, Chlorine and organic 
compounds but also prevents rigid particles >30 μm to enter the pump.  

If the resulting 

water does not fall into the SCA “core-zone” (see Figure 2) have additional treatment 

installed.  

Notes!

 

Flush the water treatment system according to the manufacturers instruction before connecting it to 
the pump-inlet. 
Make sure that the functioning of the water treatment system will be checked on a regular basis. 

Waste/drain 

The appliance has two drain hoses: one for the drip tray and one for the machine itself. These semi-
flexible hoses have an external diameter of 20 mm (inner diameter: 16 mm). The hoses must slope 
downwards all the way from machine to waste to prevent clogging. The waste at the location should 
have a minimum inside diameter of 38 mm to accommodate for the two hoses and incorporate a 
water-lock to prevent smelly odours. 

Machine location 

The machine is only to be installed in locations where it can be overseen by trained personnel. 
Areas where a water-jet could be used are not suitable as location for the machine. 

Counter surface 

The countertop must be sturdy eno

ugh to easily support the machines’ weight (when filled: up to 

100kg) plus extra equipment (one or two coffee-grinders, 

tableware, …). The surface should have a 

height of 95-100 cm and be smooth, flat and horizontal.  

It is advised to think about the location of holes in the countertop where the water and waste hoses 
and electric cables should pass before the machine is installed. 

Pump location 

There should be nearby space for the electric motor with rotary vane pump. The pump-assembly 
should not be able to touch the walls of the cabinet it is located in to prevent noise. Further noise 
reduction can be achieved by placing the assembly on a 2-4cm thick rubber-foam sheet with 
dimensions: 16x30cm (not supplied with machine). The pump will be electrically connected to the 
espresso machine with an approximately 2 m long cable.  

Areas where a water-jet could be used are not suitable as location for the pump-assembly. 

Make sure there is air-flow possible near the motor to prevent overheating. 

 

 

Содержание Mirage Slim Jim

Страница 1: ...Typ hier Typ hier Typ hier Installation manual Slim Jim espresso machines Original instructions Document ID Sup Tim Eng Date of issue December 20 2018 Revision date June 24 2020...

Страница 2: ...ity 5 Water supply 6 Water treatment system 6 Waste drain 6 Machine location 6 Counter surface 6 Pump location 6 Electric mains 7 3 phase machine 7 single phase machine 8 3 phase single phase conversi...

Страница 3: ...hildren aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning u...

Страница 4: ...riplette shot timer and or temperature 5 Capacitive interface and display of controller 6 Left hand group 3 digit display shot timer and or temperature 7 Volume toggle switch left group 8 Program cont...

Страница 5: ...ater supply and waste 15 Open water tap 16 Plug power cord onto pump motor 17 3P N E versus P N E electric mains 18 Connect machine to electric mains 19 Fill machine with water with heating circuits O...

Страница 6: ...1 Calcium Hardness 51 68 17 85 ppm Sodium 10 at or near 10 ppm Sulphate 30 0 50 ppm Chloride 0 0 30 ppm Silica 0 0 5 ppm Odour and colour clean fresh odour free clear Taste influencing organic compoun...

Страница 7: ...egular basis Waste drain The appliance has two drain hoses one for the drip tray and one for the machine itself These semi flexible hoses have an external diameter of 20 mm inner diameter 16 mm The ho...

Страница 8: ...9 7 2 3 11 6 2 6 11 4 3 1 13 4 single phase 230V L L1 6 3 27 5 6 8 29 5 7 5 32 7 8 0 34 7 N L2 6 3 27 5 6 8 29 5 7 5 32 7 8 0 34 7 Table 2 Showing peak power in the different phases for different mach...

Страница 9: ...locations wiring is a lot higher than with 3 phase power Figure 4 At left P N E at right 2P N E The machine can make use of L1 and L2 plus E without N of the right electric mains configuration Peak c...

Страница 10: ...e the shelf from the crate 4 Straighten the tabs on the two diagonally ribs of the crate 5 Undo the screws that hold the sides of the crate to the bottom 6 Remove the sides of the crate from the botto...

Страница 11: ...se one of the supplied high pressure hoses to connect the outlet of the water treatment system to the inlet of the pump The connection on the hose is a 3 8 BSPP swivel nut Note National rules regulati...

Страница 12: ...ne and the waste and make sure the hoses do not make a sharp bend or are led over a sharp angle The drain runs off best when the end of the hose is above water level in the water lock Figure 6 The dra...

Страница 13: ...hase2 Danger If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard It is advised to check an existing wall s...

Страница 14: ...again wait for the NO HEAT window then touch the NO HEAT button filling will continue after a few seconds 6 During this second filling safety level in the steam boiler will be reached and the display...

Страница 15: ...eck valve in the coffee system De activate the group lower the pump pressure and then re activate the group to check Remove the blind filter after this initial adjustment 13 Press the mix water button...

Страница 16: ...el operational window at start coffee boilers heat up faster 4 Heating up from 20 C to operational temperature will take about 15 minutes during this heat up Check expansion pressure Make sure that al...

Страница 17: ...djust controller to new flow meters 0 7mm flow meters give 3300 pulse litre 1 15mm flow meters give 2000 pulse litre 6 Adjust present time and weekday in the BARISTA LEVEL enter with password 33333 su...

Страница 18: ...te each individual group e Use a measuring cup or scales to check the free flow rate of each individual group i with 0 6mm jets it should be 100 120 ml in 15 seconds ii with 0 8mm jets it should be 20...

Страница 19: ...INSTALLATION MANUAL install Slim Jim Installation manual page 18 Figure 12 Print service record and fill out installation data Keep this with the machine...

Страница 20: ...mperature 2 pump pressure adjusted to correct brew pressure The temperature of the manifold changes during use of the machine and this variation cannot be compensated for For that reason we suggest to...

Страница 21: ...dismounted and should not be loosened to adjust the set screw Turn the cold water set screw clockwise to increase the mix water temperature and anti clockwise to reduce the mix water temperature Note...

Страница 22: ...window use EXIT to return to stand by 2 Explain profits of ECO w r t NO HEAT 3 Change individual boiler to ECO and back manipulation of the Bastone or touchpad will take the boiler out of ECO as well...

Страница 23: ...f water quality and regular checking of the water treatment system 6 Explain the owner about maintenance preventative service and emergency repairs 7 Tell the owner user what to do when there seems to...

Страница 24: ...ire Danger We cannot be held responsible for damage and or injuries resulting from actions performed on our machines by non qualified personnel Any qualified technician working on the machine is urged...

Отзывы: