background image

INSTALLATION MANUAL 

– check location 

Slim Jim Installation manual 

 

page 7 

Electric mains 

 
Rated voltage:  ~230V / 3N~400V, 50 / 60Hz 
Rated power:  max. 34.7 (230V) / 11.6 (400V) Amp per phase, see Table 2 for details. 

 

 

Danger 

If the supply cord or the pump connection cord is damaged it must be replaced by the manufacturer, 
its service agent or similarly qualified persons in order to avoid a hazard. 

The appliance is to be supplied through a residual current device (RCD) having a rated residual 
operating current not exceeding 30mA. 

 

Slim Jim  

peak power  

at 230 Vac 

         version 
per  
phase 

Duette 

Triplette 

Duette 

Triplette 

4800W steam power 

6000W steam power 

kW 

Amp 

kW 

Amp 

kW 

Amp 

kW 

Amp 

3-phase 

(3N~400V) 

L1 

2.1 

8.9 

2.1 

8.9 

2.5 

10.7 

2.5 

10.7 

L2 

2.1 

8.9 

2.1 

8.9 

2.5 

10.7 

2.5 

10.7 

L3 

2.2 

9.7 

2.3 

11.6 

2.6 

11.4 

3.1 

13.4 

(N) 

2.2 

9.7 

2.3 

11.6 

2.6 

11.4 

3.1 

13.4 

single phase 

(~230V) 

L1 

6.3 

27.5 

6.8 

29.5 

7.5 

32.7 

8.0 

34.7 

(N) 

L2 

6.3 

27.5 

6.8 

29.5 

7.5 

32.7 

8.0 

34.7 

Table 2. Showing peak power in the different phases for different machine versions. 

 
The machines’ internal electrics consists of 3 heating circuits and an operation circuit. Each circuit is 
meant to function on 230Vac. The range in which it can function safely is 208-240Vac. Electric mains 
can be connected in two ways to the machine. Check if the electric mains of the location matches the 
configuration of the machine. 

3-phase machine 

What we call a three-phase machine must be connected to 3P-N-E power (3  N 
Earth, see Figure 3) with 120 degrees phase shift between phases. Such power is characterised by: 
220-240Vac tension between each phase and neutral (or Earth) and 380-400Vac tension between the 
phases. For peak power, see Table 2. 

   

Figure 3. 3P-N-E electric mains. Peak current of the Slim Jim is 9.7 

– 13.4A per phase. 

 

 

3N~400V; 3P-N-E

N

L2

L1

L3

E

± 400V

±

0V

Содержание Mirage Slim Jim

Страница 1: ...Typ hier Typ hier Typ hier Installation manual Slim Jim espresso machines Original instructions Document ID Sup Tim Eng Date of issue December 20 2018 Revision date June 24 2020...

Страница 2: ...ity 5 Water supply 6 Water treatment system 6 Waste drain 6 Machine location 6 Counter surface 6 Pump location 6 Electric mains 7 3 phase machine 7 single phase machine 8 3 phase single phase conversi...

Страница 3: ...hildren aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning u...

Страница 4: ...riplette shot timer and or temperature 5 Capacitive interface and display of controller 6 Left hand group 3 digit display shot timer and or temperature 7 Volume toggle switch left group 8 Program cont...

Страница 5: ...ater supply and waste 15 Open water tap 16 Plug power cord onto pump motor 17 3P N E versus P N E electric mains 18 Connect machine to electric mains 19 Fill machine with water with heating circuits O...

Страница 6: ...1 Calcium Hardness 51 68 17 85 ppm Sodium 10 at or near 10 ppm Sulphate 30 0 50 ppm Chloride 0 0 30 ppm Silica 0 0 5 ppm Odour and colour clean fresh odour free clear Taste influencing organic compoun...

Страница 7: ...egular basis Waste drain The appliance has two drain hoses one for the drip tray and one for the machine itself These semi flexible hoses have an external diameter of 20 mm inner diameter 16 mm The ho...

Страница 8: ...9 7 2 3 11 6 2 6 11 4 3 1 13 4 single phase 230V L L1 6 3 27 5 6 8 29 5 7 5 32 7 8 0 34 7 N L2 6 3 27 5 6 8 29 5 7 5 32 7 8 0 34 7 Table 2 Showing peak power in the different phases for different mach...

Страница 9: ...locations wiring is a lot higher than with 3 phase power Figure 4 At left P N E at right 2P N E The machine can make use of L1 and L2 plus E without N of the right electric mains configuration Peak c...

Страница 10: ...e the shelf from the crate 4 Straighten the tabs on the two diagonally ribs of the crate 5 Undo the screws that hold the sides of the crate to the bottom 6 Remove the sides of the crate from the botto...

Страница 11: ...se one of the supplied high pressure hoses to connect the outlet of the water treatment system to the inlet of the pump The connection on the hose is a 3 8 BSPP swivel nut Note National rules regulati...

Страница 12: ...ne and the waste and make sure the hoses do not make a sharp bend or are led over a sharp angle The drain runs off best when the end of the hose is above water level in the water lock Figure 6 The dra...

Страница 13: ...hase2 Danger If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard It is advised to check an existing wall s...

Страница 14: ...again wait for the NO HEAT window then touch the NO HEAT button filling will continue after a few seconds 6 During this second filling safety level in the steam boiler will be reached and the display...

Страница 15: ...eck valve in the coffee system De activate the group lower the pump pressure and then re activate the group to check Remove the blind filter after this initial adjustment 13 Press the mix water button...

Страница 16: ...el operational window at start coffee boilers heat up faster 4 Heating up from 20 C to operational temperature will take about 15 minutes during this heat up Check expansion pressure Make sure that al...

Страница 17: ...djust controller to new flow meters 0 7mm flow meters give 3300 pulse litre 1 15mm flow meters give 2000 pulse litre 6 Adjust present time and weekday in the BARISTA LEVEL enter with password 33333 su...

Страница 18: ...te each individual group e Use a measuring cup or scales to check the free flow rate of each individual group i with 0 6mm jets it should be 100 120 ml in 15 seconds ii with 0 8mm jets it should be 20...

Страница 19: ...INSTALLATION MANUAL install Slim Jim Installation manual page 18 Figure 12 Print service record and fill out installation data Keep this with the machine...

Страница 20: ...mperature 2 pump pressure adjusted to correct brew pressure The temperature of the manifold changes during use of the machine and this variation cannot be compensated for For that reason we suggest to...

Страница 21: ...dismounted and should not be loosened to adjust the set screw Turn the cold water set screw clockwise to increase the mix water temperature and anti clockwise to reduce the mix water temperature Note...

Страница 22: ...window use EXIT to return to stand by 2 Explain profits of ECO w r t NO HEAT 3 Change individual boiler to ECO and back manipulation of the Bastone or touchpad will take the boiler out of ECO as well...

Страница 23: ...f water quality and regular checking of the water treatment system 6 Explain the owner about maintenance preventative service and emergency repairs 7 Tell the owner user what to do when there seems to...

Страница 24: ...ire Danger We cannot be held responsible for damage and or injuries resulting from actions performed on our machines by non qualified personnel Any qualified technician working on the machine is urged...

Отзывы: