INSTALLATION MANUAL
– install
Slim Jim Installation manual
page 13
First fill
1. (Verify that all 3 HEAT switches are in the OFF position: lever pointing down.)
With the water-mains open and electric mains connected, turn the main switch ON (right hand side
switch, toggle-lever up). The display will show a start-up window with software-version information
and then turn to stand-
by (“NO HEAT”).
NO HEAT
window
stand-by mode:
the boilers will not
heat up
☼
touch “NO HEAT”
2. Touch the centre button to turn the machine ON, the display will change to:
operational window
(Triplette)
temperature too low
but no heating
command
On the Duette operational window, the
GROUP 3
“button” is not present. All separator bars are grey
indicating that controller is not sending out any signal to heat.
3. At this point the pump will be activated and the steam boiler will start to fill. As the coffee system
up to now has been filled at water mains pressure, this will continue to fill due to the increased
water pressure. Listen if you can hear water flowing into the steam boiler. If you do not hear water
flowing, there may be a blockage in the fill-system that has to be resolved before continuing.
4. The controller has a safety shut-down when the fill valve is open for longer than 2 minutes. The
steam boiler will not be completely filled yet after 2 minutes and the controller will thus shut down
and the LED(s) on the Bastone units or touchpads will start flashing.
5. Switch the main switch OFF (toggle-lever down) and wait for the displays to go blank, then turn
the main switch ON again, wait for the NO HEAT window, then touch the
“NO HEAT” button: filling
will continue after a few seconds.
6. During this second filling, safety-level in the steam boiler will be reached and the display will
change (grey separator bars turn orange) to show that a heating command is given by the
controller. Since the heat switches are still in the OFF position, the boilers will not heat up yet.
NO HEAT
window
stand-by mode:
the boilers will not
heat up
☼
touch “NO HEAT”
operational window
showing boiler
temperatures and
heating command
On the Duette operational window, the GROUP 3 “button” is not present. Safety-level in steam boiler
is reached. Orange separator bars indicate that the controller is sending out signals to heat to all
boilers. Heating up will start when the HEAT switches are in the ON position (see next section).
7. Activate all groups (push-button on Bastone or upper button of touchpad) until water runs from the
group, then de-activate the groups.
8.
If the steam boiler is not yet filled after these 2 “runs”, the LED(s) will start flashing again; repeat
the turning OFF-ON procedure.
9. When the OFF-ON procedure has to be repeated more than 2 times, it is possible that the steam
boiler does not fill (quickly enough) due to blockage in the system or very low pump-pressure
setting. Check before continuing.
10. When the filling has stopped without the LED(s) flashing the steam boiler is filled up to operational
level.
11. Re-check if water is flowing from all individual groups upon activation of the groups.
SUNDAY 08 : 00
TECH. ASSISTANCE
KEES VAN DER WESTEN
SLIM JIM
NO HEAT
GROUP 1
18.6
GROUP 2
18.7
GROUP 3
18.5
STEAM
18.6
MENU
SUNDAY 08 : 00
TECH. ASSISTANCE
KEES VAN DER WESTEN
SLIM JIM
NO HEAT
GROUP 1
18.6
GROUP 2
18.7
GROUP 3
18.5
STEAM
18.6
MENU