![Kees van der Westen Mirage Slim Jim Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/kees-van-der-westen/mirage-slim-jim/mirage-slim-jim_installation-manual_3883248020.webp)
INSTALLATION MANUAL
– install
Slim Jim Installation manual
page 19
Adjust mix-water temperature
The temperature of the mix-water depends on:
1. the steam boiler temperature,
2. the temperature of the cold water,
3. the amount of mixed-in cold water, which depends on:
a. pump-pressure,
b. cold-water orifice.
4. the temperature of the inlet-manifold.
Before adjusting the mix-water temperature make sure that the machine is (otherwise) fully operational
and adjusted:
1. steam boiler at operational temperature,
2. pump-pressure adjusted to correct brew pressure.
The temperature of the manifold changes during use of the machine and this variation cannot be
compensated for. For that reason we suggest to measure the mix-water temperature of a second
dispense (appr. 100 ml) very shortly after a first dispense (100 ml) of mix-water.
The cold-water orifice can be adjusted on the inlet manifold inside the machine. The left side-panel of
the machine has to be removed to access the inlet manifold.
Figure 13. Undo the nuts and remove the left-hand side panel (when glass side panels are mounted
you have to remove the underlying support nuts as well to be able to remove the inner panel).
manifold