![Keba KeDrive D3-DA BG3 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/keba/kedrive-d3-da-bg3/kedrive-d3-da-bg3_operation-manual_3830583073.webp)
73
1 Appendix
Operation Manual KeDrive D3-DA BG3 and BG4
1804.200B.1-01 Date: 03/2023
Appendix
U
Mains
F
S
Unit
D3-DA
320/C-24xx
(BG3)
D3-DA
320/C-32xx
(BG3)
D3-DA
310/C-45xx
(BG3)
D3-DA
320/C-45xx
(BG3)
D3-DA
310/C-80xx
(BG3)
D3-DA
310/C-A3xx
(BG4)
D3-DA
310/C-B1xx
(BG4)
D3-DA
310/C-C0xx
(BG4)
Rated current
480 V
2 kHz
A
24.00
32.00
45.00
45.00
80.00
150.00
250.00
300.00
Maximum current
A
72.00
96.00
135.00
135.00
240.00
290.00
470.00
630.00
Duration of maximum current
ms
500.00
500.00
500.00
500.00
400.00
200.00
200.00
250.00
Overcurrent
A
48.00
64.00
90.00
90.00
160.00
235.00
375.00
420.00
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
Maximum current for F
M
= 0 Hz
A
56.57
75.38
106.07
106.07
180.17
252.49
356.38
415.00
Rated current
480 V
4 kHz
A
24.00
32.00
45.00
45.00
71.70
125.00
210.00
300.00
Maximum current
A
59.70
79.60
112.00
112.00
215.00
251.28
355.00
435.00
Duration of maximum current
ms
500.00
500.00
500.00
500.00
250.00
200.00
200.00
250.00
Overcurrent
A
48.00
64.00
90.00
90.00
143.40
180.00
285.00
325.00
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
Maximum current for F
M
= 0 Hz
A
44.26
58.97
83.01
83.01
141.14
185.35
244.66
255.00
Rated current
480 V
8 kHz
A
15.20
20.30
28.50
28.50
50.70
65.00
130.00
165.00
Maximum current
A
37.30
49.80
70.00
70.00
119.00
113.14
177.00
330.00
Duration of maximum current
ms
500.00
500.00
500.00
500.00
500.00
100.00
100.00
250.00
Overcurrent
A
30.40
40.60
57.00
57.00
101.40
113.14
177.00
212.00
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
Maximum current for F
M
= 0 Hz
A
27.15
36.20
51.05
51.05
86.69
105.67
140.01
135.00
Rated current
480 V
12 kHz
A
8.70
11.70
16.40
16.40
29.20
–
–
–
Maximum current
A
26.70
35.60
50.00
50.00
85.00
–
–
–
Duration of maximum current
ms
500.00
500.00
500.00
500.00
500.00
–
–
–
Overcurrent
A
17.40
23.40
32.80
32.80
58.40
–
–
–
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
–
–
–
Maximum current for F
M
= 0 Hz
A
17.54
23.48
32.95
32.95
56.14
–
–
–
Rated current
480 V
16 kHz
A
6.10
8.20
11.50
11.50
20.40
–
–
–
Maximum current
A
19.70
26.30
37.00
37.00
62.90
–
–
–
Duration of maximum current
ms
500.00
500.00
500.00
500.00
500.00
–
–
–
Overcurrent
A
12.20
16.40
23.00
23.00
40.80
–
–
–
Duration of overcurrent
s
10.00
10.00
10.00
10.00
10.00
–
–
–
Maximum current for F
M
= 0 Hz
A
12.30
16.40
23.05
23.05
39.17
–
–
–
Remarks
: Current data per axis in the axis controller 400/480 V AC relate to the feed voltage for the supply unit, firmware release V003.30.00
Table A.3 Current data, KeDrive D3-DA axis controllers BG3 and BG4, liquid-cooled
Содержание KeDrive D3-DA BG3
Страница 1: ...Operation manual Compact multi axis system KeDrive D3 KeDrive D3 DA Axis Controller BG3 and BG4...
Страница 14: ...14 1 Safety Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Safety...
Страница 24: ...24 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...
Страница 66: ...66 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...
Страница 78: ...78 1 Appendix Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Appendix...
Страница 82: ...82 1 Glossary Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023 Glossary...
Страница 83: ...83 1 Operation Manual KeDrive D3 DA BG3 and BG4 1804 200B 1 01 Date 03 2023...