68
DESCRIPTION Of THE TERMINALS
6.3.4 Diagnostic interface X6A
The socket X6A is a serial RS232/485 interface. It serves for the connection of the con-
trol with a PC or other operating units via the protocol DIN66019II. The control unit has
the node address 0, the drive unit has the node address 1. Alternatively, this interface
can be accessed by the IEC control program as desired, thus providing many different
protocol variants (library "SysCom“).
X6A
Name
Description
Socket D-SUb-9
1
PGM
Don't connect !
5
4
3
2
1
9
8
7
6
2
TxD
Transmission signal RS232
3
RxD
Receive signal RS232
4
RxD-A
Receive signal RS485 A
5
RxD-B
Receive signal RS485 B
6
PGM+
Don't connect !
7
DGND
Data reference potential
8
TxD-A
Transmission signal RS485 A
9
TxD-B
Transmission signal RS485 B
Housing
GND
Housing is connected internally
to the drive controller PE.
Figure 51: Diagnostic interface X6A
RS 232 cable 2.8 m
Mat.No:
0058025-001D
0058025-001D
1
5
6
9
1
5
6
9
Figure 52: RS232 cable for diagnostic interface
The maximum cable length at X6A must not exceed 30 m.