DIMENSIONS AND WEIGHTS
3.4.2 Mounting cutout housing G
M6
Figure 7:
Mounting cutout for COMBIVERT P6 (provided by customer)
NOTICE
Ensure correct material thickness !
The material thickness of the cabinet back wall and the mounting meth-
od must be chosen that way the material does not bend. Together with
the rubber seal of the P6, protection class IP54 is maintained. If the ma-
terial thickness exceeds 8 mm (18 / 19P6) or 14 mm (23P6), the P6 must
be removed from the cabinet prior to replacing the heatsink fan.
NOTICE
Observe fan direction !
The installation of the drive controller in the control cabinet and its in-
stallation in the wind turbine must be carried out such that the fan axis
of the drive controller is parallel to the rotational axis of the hub of the
wind turbine.