67
DESCRIPTION Of THE TERMINALS
6.3.3.2 Pin assignment encoder channel 2 (X3B)
Socket D-SUb-9
5 4 3 2 1
9 8 7 6
PIN
Incremental encoder TTL
SSI
1
A+
Input channel A
CL+
Output clock signal
2
B+
Input channel B
DAT+
Input data channel
3
N+
Input zero track
–
4
5V
Voltage output 5 V
5V
Voltage output 5 V
5
24V Voltage output 24 V
24V
Voltage output 24 V
6
A-
Differential signal to A+
CL-
Differential signal to CL+
7
B-
Differential signal to B+
DAT-
Differential signal to DAT+
8
N-
Differential signal to N+
–
9
COM Reference potential
COM
Reference potential
Housing
GND Shielding of the encoder cable. Housing is connected internally to the drive controller
PE.
Figure 49: Pin assignment encoder channel 2 (X3B)
6.3.3.3 Encoder cable
General information on connecting encoder cables:
• Use encoder cable double shielded and twisted in pairs.
• Connect outside shield to GND at both ends. At the drive controller end, connect
outside shield either
- onto the shield connection rail using shield connection clamps
or
- to the housing of the SubD plug (connect inside the plug).
• Connect interior shielding at one side at the inverter to COM.
• Do not connect outside and inside shield!
GND
GND
A+, A-
B+, B-
N+, N-
COM
5/24V
Figure 50: Example for wiring an encoder cable