A pre-saved paramet
er file can be used to create custom defaults settings.
The pre-saved parameter file can either be created using the Combivis
computer program or taken as an upload from a drive already programmed.
The file type needs to be .dw5.
The .dw5 file must then be saved to the keypad operator flash memory.
The .dw5 file must be transferred via FTP.
To save the custom parameter list text file to flash, OEM password level is
required. From the Programming Menu, the ‘File’ option (F4) will then be listed.
Under the ‘File’ list, select ‘File Operations’. Under ‘File Operations,’ select
‘FTP’(F2). When the .dw5 file has been transferred to the keypad operator flash
memory, select ‘Menu’ (F1), then ‘Prog’ (F1) to return to the Programming Menu.
To load the .dw5 parameter file to the keypad operator, set CH03 Restore
Parameters = Load Motor Data.
To save the current settings as the new defaults, set US05 = Create OEM
Default.
To revert to the custom .defaults, set CH03 = Factory Reset or US05 = Restore
OEM Defaults