324
Parameter Reference
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Para.
Name
Hex
v1.72
Motor/Gear Type
Setting
Options
NUM
Range
Units
Default
Pass
Level
I
IX
P
PX
Min.
Max.
Imp.
Met.
FB51
Temp DIN Com Err. Serv.
12B3
-
-
0
128
-
-
0
OEM
FB52
Temp DIN Com Err. Ack.
12B4
-
-
-32768
32768
-
-
0
OEM
FB53
Temp DIN Com Err. Val.
12B5
-
-
-2147483647
2147483647
-
-
0
OEM
FB54
RS485 Mode
12B6
Full Duplex
Half Duplex
0
1
0
1
-
Full Duplex
OEM
FB55
Software Filter
12B7
-
-
0: Off
255
ms
0: Off
OEM
TS01
NTSD Mode
1381h
External
Threshold 1
Threshold 2, Binary Encoded
Threshold 3, Binary Encoded
One switch per threshold
0
1
2
3
4
0
4
-
-
External
OEM
TS02
NTSD Target Speed
1382h
-
-
0
1600
ft/min
-
0
OEM
0.000
8.128
-
m/s
0.000
TS03
NTSD Speed 1 Up
1383h
-
-
0
1600
ft/min
-
0
OEM
0.000
8.128
-
m/s
0.000
TS04
NTSD Speed 2 Up
1384h
-
-
0
1600
ft/min
-
0
OEM
0.000
8.128
-
m/s
0.000
TS05
NTSD Speed 3 Up
1385h
-
-
0
1600
ft/min
-
0
OEM
0.000
8.128
-
m/s
0.000
TS06
NTSD Speed 1 Down
1386h
-
-
0
1600
ft/min
-
0
OEM
0.000
8.128
-
m/s
0.000
TS07
NTSD Speed 2 Down
1387h
-
0
1600
ft/min
-
0
OEM
0.00000
8.128
-
m/s
0.000
TS08
NTSD Speed 3 Down
1388h
-
0
1600
ft/min
-
0
OEM
0.00000
8.128
-
m/s
0.000