114
US - Basic Setup Parameters
Absolute Analog Speed
A uni-polar 0...+10VDC analog signal connected to terminals AN1+ and AN1-
controls the speed from 0...High Speed. The High Speed must be set in
LS02. For controllers which do not output 10V corresponding to High Speed,
the analog input can be scaled by LA05 AnIn1 Gain. In addition, the AN1+
and AN1- inputs can be programmed to receive the speed pr
ofile as either a
voltage or current signal using parameter LA50.
The speed profile acceleration, deceleration and jerk rates are externally
generated by the controller. It is possible to limit external profile rates by
setting LS15 = Internal Profile (4) and adjusting the according LS20-25 High
Speed profile rates.
The direction is determined by digital inputs assigned in LI04-11 as Up (25)
and Down (26). Both direction signals cannot be signaled simultaneously at
the beginning of a run, otherwise ‘Direction Selection Failure’ will occur.
Bi-polar Analog Speed
A bi-polar, 0... ±10V analog signal connected to the terminals AN1+ and AN1-
controls the speed from 0...±High Speed. The High Speed must be set in
LS02. For controllers which do not output 10V corresponding to High Speed,
the analog input can be scaled by LA05 AnIn1 Gain. In addition, the AN1+
and AN1- inputs can be programmed to receive the speed profile as either a
voltage or current signal using parameter LA50.
The speed profile acceleration, deceleration and jerk rates are externally
generated by the controller. It is possible to limit external profile rates by
setting LS15 = Internal Profile (4) and adjusting the according LS20-25 High
Speed profile rates.
The direction is determined by the polarity of the analog signal, although a
direction input is needed to control the start and stop routines. A digital input
must be assigned in LI04-11 as Up (25) or Down (26). Either or both Up and
Down inputs can be assigned but the direction selected does not matter since
the actual direction is determined by polarity of the analog signal. If both
directions are assigned as inputs, they cannot be signaled simultaneously at
the beginning of a run, otherwise ‘Direction Selection Failure’ will occur.
Содержание COMBIVERT F5
Страница 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Страница 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Страница 347: ...Notes...