258
DG - Diagnostics Parameters (Combivis only)
The Active Pr
ofile displays which speed profile is active.
Value: Description:
0
None
1
Inspection
2
High Speed
4
One Floor
8
Emergency
16
Correction
32
Emergency Slowdown
The Active Speed displays which selected speed is active.
Value: Description:
0
None
32
Inspection Speed
64
Leveling Speed
96
Correction Speed
128
High Speed
160
Intermediate Speed 1
256
Earthquake Speed
384
Intermediate Speed 2
512
Emergency Generator Speed
640
Intermediate Speed 3
768
UPS Speed
Displays the car load percentage.
DG52
Active Profile
DG53
Active Speed
DG58
Car Load