317
Parameter Reference
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Para.
Name
Hex
v1.72
Motor/Gear Type
Setting
Options
NUM
Range
Units
Default
Pass
Level
I
IX
P
PX
Min.
Max.
Imp.
Met.
LT12
Current Hold Time
0E8C
LF78
-
-
0.00
2.00
sec
0.50
Adjuster
LT13
Current Ramp Down Time
0E8D
LF79
-
-
0.10
2.55
sec
0.30
Adjuster
LT15
AFE HV Idle Time
0E8F
-
-
-
0.00
Always On
sec
0-Always on
OEM
LT30
OLED Run Time
0E9E
-
-
-
0.00
65535
sec
0.600
OEM
LT31
OLED Constant Speed
Delay
0E9F
-
-
-
0.00
65535
sec
0.200
OEM
LP01
Positioning Control
0C81
LP1
Off
Posi One Floor
Learn Slowdown
Position Value Reset
0
1
2
3
-
-
-
-
Off
Basic
LP02
Minimum Slowdown
Distance
0C82
LP2
RO
RO
RO
RO
-
-
0.00
600.00
in
-
0.00
Basic
0.0
-
0.0
LP03
High Speed Slowdown
Dist.
0C83
LP3
-
-
0.00
600.00
in
-
0.00
Basic
0.0
-
0.0
LP04
Short Floor Slowdown
Distance
0C84
-
-
-
0.00
600.00
in
-
0.00
Basic
0.0
-
0.0
LP05
Correction Distance
0C85
LP4
-
-
0.00
25.00
in
-
0.00
OEM
0.0
-
0.0
LP06
Scaling Increments High
0C86
LP21
-
-
0
9999
-
-
0
Adjuster
LP07
Scaling Increments Low
0C87
LP22
-
-
0
9999
-
-
0
Adjuster
LP08
Scaling Distance
0C88
LP23
-
-
0.00
600.00
in
-
0.00
Adjuster
0.0
15240.0
-
mm
0.0
LP10
Floor Number
0C8A
-
Not yet implemented
-
1
30
-
-
1
-
LP11
Floor Enable
0C8B
-
Not yet implemented
Disabled
Enabled
0
1
-
-
-
-
Disabled
-
LP12
Floor Position
0C8C
-
Not yet implemented
-
0.0
6553.5
in
-
0.0
-
-
LP13
Correction Distance Up
0C8D
-
Not yet implemented
-
0.0
25.0
in
-
0.0
-
-
LP14
Correction Distance Down
0C8E
-
Not yet implemented
-
0.0
25.0
in
-
0.0
-
-
LP15
Max Floor Speed
0C8F
-
Not yet implemented
-
0
1600
ft/min
-
0
-
0.00
8.00
-
m/s
0.00
LP16
Floor Label
0C90
-
Not yet implemented
-
1
65535
-
-
1
-
LP18
Leveling Distance
0C92
-
Not yet implemented
-
0.0
12.0
in
-
0.0
-
-
LP19
Re-leveling Distance
0C93
-
Not yet implemented
-
0.0
3.0
in
-
0.0
-
-
LP20
Position Feedback Source
0C94
-
Not yet implemented
Motor Encoder
Encoder 2
CAN Encoder
0
1
2
-
-
-
-
Motor
Encoder
OEM
LP21
Reference Floor
0C95
-
Not yet implemented
-
0
30
-
-
1
OEM
LP22
Reference Direction
0C96
-
Not yet implemented
Up
Down
Up + Down
0
1
2
-
-
-
-
Up
OEM
LP23
Reference Speed
0C97
-
Not yet implemented
-
0
1600
ft/min
-
0
OEM
0.00
8.00
-
m/s
0.00
LP24
Kp Position Acceleration
0C98
-
Not yet implemented
-
0
32767
-
500
OEM
LP25
Kp Position Deceleration
0C99
-
Not yet implemented
-
0
32767
-
500
OEM
LP26
Kp Speed Limit Reduction
0C9A
-
Not yet implemented
-
0
100
%
100
OEM
LP27
Limit for p/s control
0C9B
-
Not yet implemented
-
0
100
%
10
OEM
Содержание COMBIVERT F5
Страница 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Страница 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Страница 347: ...Notes...
Страница 348: ......