Errata
(v3.32) Rev1B Corrections
Section 2.6:
Added 230V R housing peak unit dimensions and weight.
Section 2.7:
Corrected drive / motor wiring diagrams - removed line contactor.
Section 2.8:
Corrected part# on page 31.
Section 4.2:
Corrected the X6C / X6D pin out - A-/B+ for RxD and TxD were backwards.
Section 4.8:
Updat
ed 4.8.1 - a .txt file can be created by pressing F4.
Section 5.12:
Updated 5.12.2 - adjust internal pretorque by delaying the pattern using
LT02 & LT03. Added section 5.12.4 Digital Pretorque description; 5.12.5 updated
Predictive Synthetic Pretorque - the function now works for either commanded
direction.
Section 6:
Corrected ETS description - if using Analog control and the command
speed goes below the LS01 speed, the drive will continue at leveling speed.
Section 6.2:
Updated LI50 Easy Direction to include Serial Speed control modes.
Clarified that the function is not available for Bi-Polar Analog control.
Section 6.3:
Corrected the torque limit curve diagram to show LM24. Removed LM26.
Section 6.7:
Clarified LL15-LL16 Overspeed Test description - command speed will
not be scaled for Analog or Serial control modes if LL15= 2 - controller will command
overspeed level.
Section 6.8:
Corrected default setting of LC32 - should be 0.5%
Section 6.9:
Corrected LT02 description - the LT01 timer is not part of the total
control hold off time.
Section 6.12:
Updated CH01 description - default settings are created by the user
using US05= 8(Create OEM default)
Section 6.16:
Added DG79,DG93,DG94 to the DG parameter list and table. Corrected
DG51 status table - Tune Pole Post value should be 102.
Section 7.2:
Corrected Analog Signal Failure description - removed Serial Speed
Modes. Corrected Modulation Grade Limit description - refers to LM22 but should
refer to LM24. Added solution: reduce LM25 field weakening speed. Added solution
to error low motor current section: increase LC32.
Section 8.2:
Corrected crossover parameters - LM22, LM24,.LM25, LM26, LC12,
LF78, LA15, LA17, LX07, DG01, DG19-21, DG33-37, DG39-40, DG42-44, DG09-10,
DG32, DG42, DG45
(v3.32) Rev1A Corrections
Powerstage:
Updated braking resistor specs for size 26 U housing drives.
Initial Start Up:
Added instructions on how to upload/download LCD keypad
parameters.
Section 6.2:
Updated UPS Operation Easy Direction information and LI50 UPS
Mode to include Open Loop Easy Direction function (OLED). Added 125% load NTS
test function.
Section 6.8:
Updated LC01 control settings information related to OLED function.
Section 6.9:
Added parameters LT15 AFE HV Idle Time, LT30 OLED Run Time and
LT31 OLED Constant Speed Delay to timer parameters.
Section 6.15:
Corrected the
PDI / PDO flow chart - the PDO section was reading as PDI.