1) The 28 W housing can either be fed with one large set of wires or two smaller sets of wires, double feed. See Mat. No. 00F50EB-KW00 from KEB.
2) The wire gauge is based on the maximum fuse rating, copper wire with a 75°C insulation rating, THHW, or equivalent. If circuit protection is selected based on the actual
input current, the wire size could be reduced.
3) This is the peak output current limited by hardware regulation. The software current control reserves 5% for closed loop regulation.
4) This is the maximum carrier frequency the power stage can support. The actual operating carrier frequency is adjusted and limited by the control card.
5) This is the power dissipation at the rated carrier frequency, rated voltage, and rated load. Operation at reduced carrier frequencies or reduced load will decrease this value.
6) 12kHz
7) Max motor cable length when using shielded cable, KEB EMI filter, and the installation must conform to EN55011 / EN55022.
8) Min. resistance applies to 50% duty cycle.
Inverter Size
20
22
24
26
28
Max Motor Power
[hp]
50
75
125
175
250
Housing Size
H
R
U
U
W
Unit Hardware
B
B
D
B
B
D
B
Input Ratings
Supply voltage [V]
305...528 ±0 (480 V Nominal voltage )
Supply voltage frequency [Hz]
50 / 60 +/- 2
Input phases
3
3
3
3
3 or 2x3
1)
Rated input current 400VAC [A]
83
127
198
275
385
(UL) Rated input current 480VAC [A]
72
105
172
231
362
UL minimum wire gauge
2)
[awg]
12
6
2
2
16mm stud terminals. Use UL
approved ring crimp connector
UL maximum wire gauge
2)
[awg]
0
1/0
4/0
300 kcmill
Output Ratings
Rated output power [kVA]
52
80
125
173
256
Rated motor power [kW]
37
55
90
132
200
Rated output current 400VAC [A]
75
115
180
250
370
(UL) Rated output current 480VAC [A]
65
96
172
231
332
Peak current (30 seconds)
3)
[A]
135
172
230
270
375
450
740
Over current fault (E.OC) trip level [A]
162
207
276
324
450
540
888
Output voltage [V]
3 x 0…Vsupply
Output frequency [Hz]
Generally 0 to 599Hz (limited by control board and carrier frequency)
Rated switching frequency
4)
[kHz]
4
8
8
8
4
4
2
Maximum switching frequency [kHz]
16
16
16
8
8
12
8
Power loss at rated operation
5)
[W]
900
1500 1500 2400 2800 2800
3500
Stall current at 4kHz [A]
83
115
173
198
330
330
574
Stall current at 8kHz [A]
83
115
150
180
180
225
407
Stall current at 16kHz [A]
45
63
98
–
–
125
6)
–
Braking Circuit
Min. braking resistance [Ohm]
9
7.5
4
2.2
8)
1.2
Typ. braking resistance [Ohm]
13
9
6
4.3
2.3
Max. braking current [A]
90
104
200
364
660
Installation Information
Max. shielded motor cable length
7)
[ft]
165
Tightening torque for power terminals [in lb]
35
53
133
220
Environmental
Max. heat sink temperature TOH [°C]
90°C / 194°F
60°C / 140 °F
90°C / 194 °F
Storage temperature [°C]
-25...70 °C / -13…158°F
Operating temperature [°C]
-10...45 °C / 14…113°F
Housing design / protection
Chassis / IP20 / Pollution Degree 2
Relative humidity
max. 95% without condensation
Approvals
Tested in accordance with…
EN 61800-3 /UL508C
Standards for emitted interference
EN 55011 Class B / EN 55022 Class A
Standards for noise immunity
IEC 1000-4-2 / -3 / -4 / -5/ -6
Climatic category
3K3 in accordance with EN 50178