336
Errata
Section 6.2:
LI03 = B(Level - Inspection - Correction), NUM = 3, changed to Decode
with LI16.
Section 6.2:
Main Contactor Check output function signaling and connection correct;
output turns on at Dir
Speed
, not Dir Enable and enable should be
connected to
NC
contact, not NO.
Section 6.2:
Main Contactor Control input function wiring corrected; input should
come from
NC
contact, not
NO
contact.
Section 6.2:
Main Contactor Input
wiring diagram updated.
Section 6.4:
LE35 selections changed.
Section 6.6:
ETS pr
ofile rates changed to LS33-35 One Floor from LS48-49 ESD
rates; NTS profile rates changed to LS48-49 NTS/ETS rates from LS33-35 One Flloor.
Section 6.9:
Timing Diagram updated; LT02 and LT12 timers.
Section 6.11:
LX17, 19, 20 description changed from ETS to NTS.
Section 6.14:
Timing Diagram updated; LT02 and LT12 timers.
Section 6.14:
Main Contactor Control signaling description corrected; output turns
on at Dir
Speed
, not Dir Enable.
Section 6.14:
Cabinet Fan On heatsink temperature output condition changed from
45 to 40 degrees Celsius.
Содержание COMBIVERT F5
Страница 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Страница 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Страница 347: ...Notes...