256
DG - Diagnostics Parameters (Combivis only)
The displayed numerical value is the sum of the individual output
weightings. For example, DG11 = 12 = Relay 1 (4) + Relay 2 (8).
Value:
Description:
0
None
1
Output 1
2
Output 2
4
Relay 1
8
Relay 2
The displayed numerical value is the sum of the individual output condition
weightings.
Value: Description:
0
None
1
Condition 0
2
Condition 1
4
Condition 2
8
Condition 3
16
Condition 4
32
Condition 5
64
Condition 6
128
Condition 7
The Parameter Set indicates the state of the run sequence in the drive. This
diagnostic parameter only applies to control modes US04 Control Type =
Binary Speed Selection (1) and Digital Speed Selection (0).
Value: Description:
1
Pre-torque
2
Normal Acceleration
3
Normal Deceleration
4
One Floor Acceleration
5
One Floor Deceleration
6
Emergency Acceleration
7
Emergency Deceleration
This shows the calculated elevator speed in either FPM or m/sec
DG11
Output Status
DG16
Output Condition State
DG19
Parameter Set
DG50
Elevator Speed
parameter