GB - 29
Error and Status Display
Display COMBIVIS display
dec hex Meaning
rAcc
reverse acceleration
67 43 Acceleration with the adjusted ramps in counterclo-
ckwise direction of rotation (reverse).
rcon
reverse constant
69 45
Acceleration / deceleration phase is completed and it
is driven with constant speed / frequency in counter
-
clockwise direction of rotation (reverse).
rdEc
reverse deceleration
68 44 Stopping with the adjusted ramps in counterclockwise
direction of rotation (reverse).
SLL
stall
71 47 This message is displayed if during constant operation
the load is limited to the adjusted current limit.
SSF
speed search
74 4A Speed search function active, that means that the
inverter attempts to synchronize onto a running
down motor.
STOP quick stop
79 4F The message is output if as response to a warning
signal the quick-stop function becomes active.
E. EF
Error ! external fault
31 1F An external signal has released an error at a pro-
grammable input.
E. Pu
Error ! power unit
12 0C General power circuit fault (e. g. fan)
E.Acc
Error ! maximum
acceleration
24 18
Acceleration exceeds the limit defined by Pn.79.
E. br
Error ! brake
56 38 This error can occur in the case of switched on brake
control.
The absence of a motor phase was detected at
brake release.
The load reaches the hardware current limitation at
brake release.
The load is below the minimum load level at brake
release.
E.buS Error ! Watchdog
18 12 Adjusted monitoring time (Watchdog) of communica-
tion between operator and PC / operator and inverter
has been exceeded. Check wiring and bus master
(PC or SPS).
E.Cdd Error ! calc. drive data 60 3C
Error: During the automatic motor stator resistance
measurement.
E.dOH Error ! Motor tempe-
rature
9
9
Error: Overtemperature of motor PTC. Error can only
be reset at E.ndOH, if PTC is again low-resistance.
No motor overheat connected, but activated in the
parameter. Install bridge between T1/t2.
resistance at the terminals T1/T2 >1650 Ohm
line breakage to the temperature sensor
Check motor cooling
motor overloaded
further on next side