GB - 22
CP-Parameter
5.
Parameter Description
CP-Parameter
1)
Setting Range Resolu-
tion Default
Unit
2)
↵
3)
Based
on
CP.00 Password input
0…9999
1
–
–
– ud.01
CP.01 Actual frequency display
-400…400
0.0125
0
Hz
–
ru.03
CP.02 Set frequency display
-400…400
0.0125
0
Hz
–
ru.01
CP.03 Inverter status
0…255
1
0
-
–
ru.00
CP.04 Apparent current
0…6553.5
0.1
0
A
–
ru.15
CP.05
Apparent current / peak value
0…6553.5
0.1
0
A
–
ru.16
CP.06
Utilization
0…65535
1
0
%
–
ru.13
CP.07 DC link voltage
0…1000
1
0
V
–
ru.18
CP.08
DC link voltage / peak value
0…1000
1
0
V
–
ru.19
CP.09 Output voltage
0…778
1
0
V
–
ru.20
CP.10 Minimal frequency
0…400
0.0125
0
Hz
– op.06
CP.11 Maximum frequency
0…400
0.0125
70
Hz
– op.10
CP.12 Acceleration time
0.00…300.00
0.01
5
s
– op.28
CP.13
Deceleration time (-0.01=CP.12) -0.01…300.00
0.01
5
s
– op.30
CP.14 S-curve time
off; 0.01…5.00
0.01
off
s
– op.32
CP.15 Boost
0.0…25.5
0.1
LTK
%
–
uf.01
CP.16 Rated frequency
0…400
0.0125
50
Hz
–
uf.00
CP.17
Voltage stabilization
0…649, off
1
off
V
E
uf.09
CP.18 Switching frequency
0…LTK
1
LTK
–
E
uf.11
CP.19 Fixed frequency 1
-400…400
0.0125
5
Hz
– op.21
CP.20 Fixed frequency 2
-400…400
0.0125
50
Hz
– op.22
CP.21 Fixed frequency 3
-400…400
0.0125
70
Hz
– op.23
CP.22
DC braking / mode
0…9
1
7
–
E pn.28
CP.23
DC braking / time
0.00…100.00
0.01
10
s
– pn.30
CP.24 Max. ramp current
0…200
1
140
%
– pn.24
CP.25 Max. constant current
0…200
1
200:off
%
– pn.20
CP.26
Speed search / condition
0…15
1
8
–
E pn.26
CP.27
Motor protection / response
0…6
1
6
–
– pn.14
CP.28
Motor protection / mode
0…1
1
1
–
–
dr.11
CP.29
Motor protection / rated current
0.0…370.0
0.1
LTK
A
–
dr.12
CP.30
Analog output / function
0…26
1
2
–
E an.31
CP.31
Analog output / amplification
-20.00…20.00
0.01
1
–
– an.33
CP.32
Transistor output / function
0…80
1
20
–
E do.00
CP.33
Relay output / function
0…80
1
4
–
E do.02
CP.34
Relay output / switching level
±30000.00
0.01 100.00
–
–
le.02
CP.35 Set value selection
0…2
1
0
–
E an.00
CP.36
Select 50/60Hz mode
4)
0…1
1
0
–
E ud.06
1) The CP-Parameter group is a selection of more than 500 parameters and 8 parameter sets for simple applications.
Each CP-Parameter (not CP.00) can be individually assigned so a special final customer menue is generated.
Further documentation is specified at the end of this manual.
2) ENTER parameter see 4.2.1
3) The origin parameters are indicated in the service menue (CP_SE) and in the application menue.
4) Only housing B