MCAC-ATSM-2017-08 Aqua Tempo Power Series (with LAK) air cooled scroll chiller unit (50Hz)
111
NOTE:
In operating, press the key "CANCEL", to turn back to the previous step or the normal display interface.
1.Before power failure of the heating water system or wired controller, the wired controller memorizes the
status of the unit automatically, and sets the water temperature value except timing on/off function. After
being powered on, the wired controller will send the relevant signals to the heating water system according
to memorized status before power failure, in order to ensure that the unit can run in the originally set status
after restoration of the power supply.
2. In the normal status, the background light is off. Press any key can only turn on the background light .
3. In order to protect the equipment, it is not allowed to change the running mode quickly or frequently. It
should operate the wired controller to start up the unit after 3 minutes later or all units are shutdown.
4. The wired controller and the outdoor unit must connect with the same power supply, powered up and
powered off simultaneously. It is not allowed to cut off the power supply separately.
5. When several wired controllers are parallel connected, the timing message can’t communicating in these
wired controllers, and the timing will work separately. In order not to confuse, we suggest set the timing
message on one wired controller for the reason of indoor unit performance is compliance with the sequence
of setting time.
6.During changing or installing the battery, pay attention to the “+”,“-” poles of the battery and install it
correctly, or will damage the control panel or battery, even worse will put lives at risk.
Note
The gateway will be used with wired controller together The K01-LON KEM gateway can be use
independently without wired controller , as below:
Wired controller
K01-LON KEM
gateway
K01-BACNET
KEM
gateway
Network control
software
MODBUS gateway
KCCH-02 PS
√
√
√
×
KCCHT-02
√
×
×
√
Содержание KEM-30 DNH3
Страница 2: ......
Страница 5: ...2 1 2 External appearance KEM 130 HN3 KEM 200 HN3 KEM 250 HN3 KEM 30 DHN3 KEM 65 DHN3 ...
Страница 33: ...30 130kW module ...
Страница 34: ...MCAC ATSM 2017 08 Aqua Tempo Power Series with LAK air cooled scroll chiller unit 50Hz 31 200kW module ...
Страница 35: ...32 250kW module ...
Страница 39: ...36 200kW module ...
Страница 40: ...MCAC ATSM 2017 08 Aqua Tempo Power Series with LAK air cooled scroll chiller unit 50Hz 37 250kW module ...
Страница 73: ...130kW module 200kW module Input of airflow Input of airflow Input of airflow Input of airflow ...
Страница 159: ......
Страница 160: ......