background image

12

13

User

'

s Manual 

KaWe MASTERLIGHT HL / LED Examination Lamp

   

2. SHORT DESCRIPTION OF THE LAMP  

KaWe MASTERLIGHT HL / LED

Intended use of the KaWe MASTERLIGHT HL / LED: 

These lamps 

were developed to illuminate an examination or treatment area in hos-
pitals or doctors’ surgeries.

Information pertaining to the operation of the KaWe MAS-
TERLIGHT HL / LED lamp:

 These lights are intended to be used to il-

luminate the area on a patient’s body requiring examination with a 
shadow-free, high-power light.
The examination lamp is only to be used by professional or trained per-
sonnel.

General product description

•  The lights are intended to be used as a tool to aid in treatment and 

diagnosis.

•  These lights are used in medical rooms.
•  The lights are mounted on a floor stand, the wall, a table, supply 

tracks, round or square posts, or a mounting plate.

•  The lights are to be serviced every two years; if damaged during use, 

immediately.

•  The electrical connection is provided via a patch cord. In order to dis-

connect the device from the electric grid, please remove the plug 
from the wall outlet. 

•  For further questions or repair, if necessary, please contact your dealer.
•  KaWe MASTERLIGHT HL - adapter:
  INPUT: 100-240V~ 50Hz 0.5A MAX
  OUTPUT: 12V~ 5.0A MAX
•  KaWe MASTERLIGHT LED - adapter:
  INPUT: 100-240V~ 47-63Hz 0.7-0.35A
  OUTPUT: 12V   2.08A MAX

   

3. LIST OF INCLUDED PARTS

•  1x floor stand mounting block
•  2x feet with locking castors
•  3x feet without locking castors
•  1x stand post
•  1x stand cap
•  1x fillister head screw with washer
•  1x flat spanner
•  Lamp body with arm
•  User's manual 

General instructions

•   All KaWe floor lamps come equipped with all of the parts required 

for assembly and connection.

•   Due to packaging requirements, the five-footed base of the stand 

comes unassembled. The stand post is always delivered as one piece 
and needs only to be connected to the base with the fastening 
screw, which is found on the bottom of the post.

•   The lamp includes an integrated power cable and shock-proof plug.
•   The type of outlet used must be installed in a manner that complies 

with IEC and VDE 0100-710 requirements.

Symbol key: 

Manufacturer

Date of manufacture

LOT

Lot code

Heed the User's Manual

Caution! During assembly and when replacing bulb

Temperature limit

Separate disposal of electric and electronic devices

Complies with relevant EU guidelines

Electric voltage warning

Alternating current

Bulb

Device safety class: II   

Hot surface

Keep dry

Electromagnetic field warning

Only use device in dry rooms

10

Environmentally-friendly material

Guideline compliance (certificates):

China

UkrTEST (Ukraine)  

USA

GOST-R (Russia)  

Dear Customer, thank you for choosing a KaWe product. Our products 
are known for their high quality and longevity. 

  

Please read these instructions thoroughly and carefully 

before attempting to use this product and heed the given 
instructions for the care of the product! 

Advantages of LED technology:

 a bulb life of at least 40,000 hours, 

very bright light and hardly any noticeable heat build-up on the sur-
geon’s forehead or on the area of the patient’s body that is being exam-
ined. The advantages of KaWe’s conventional illumination technology 
with halogen bulbs have been maintained: natural colour reproduc-
tion, exact illumination of the treatment area and easy positioning of 
the lamp body.

 

1. SAFETY INSTRUCTIONS

When handling the light, the instructions given in the User

'

s Manual 

must be followed.

WARNING : This device is not intended for use in areas in 
which explosions may occur. This lamp is classified as a class 
1 device according to the medical products law.

Please read these instructions thoroughly and carefully and familiarise 
yourself fully with this product before using it in order to benefit from 
all the advantages of the lamp system and to avoid the possibility of 
damaging it.

Maintenance work on the lamp, especially assembly, is only to be car-
ried out by authorised personnel.  

The safety of the lamp is only guaranteed by the manufacturer if repairs 
and changes are performed by the manufacturer itself or by a location 
that guarantees that the safety rules will be followed.

WARNING: The lamp may not be modified in any way!

The manufacturer is not responsible for damage to persons or other 
objects if the lamp is used incorrectly or for a non-intended purpose. 
The KaWe MASTERLIGHT HL / LED cannot be combined with any other 
devices.

Prior to each use, check the lamp to ensure that it is in perfect working 
order. 

Table of contents

1.   Safety instructions  ...................................................... page   12
2.   Short description of the lamp:
 

KaWe MASTERLIGHT HL / LED  .................................... page   13

3.   List of included parts ................................................... page   13
3.1   Assembly instructions: 5-foot-base ..........................   page   14
3.2   Assembly instructions: table top mount   ................... page   15
3.3   Assembly instructions: wall mount  ............................ page   16
3.4   Replacing the bulb   ..................................................... page   17
4.   Cleaning  ...................................................................... page   17
4.1   Floor stand ................................................................... page   17
4.2   Light body   .................................................................. page   17
4.3   Examination lamp ........................................................ page   17
5.   Technical data   ............................................................. page   17
6.   Maintenance  ............................................................... page   17
6.1    Regular maintenance requirements  ......................       page   17
7.   Electrical installation information .........................        page   18
7.1   Environmental conditions  ........................................... page   18
7.2   Instructions on packaging  .......................................... page   18
7.3   Important information  ................................................ page   18
8.   CE-label  ....................................................................... page   18
9.   Disposal  ....................................................................... page   18
10.   Tables: 
 

Electromagnetic compatibility tables  ......................... page   18

11.   Warranty  ...................................................................... page   21

5-foot floor stand

Wall mount

Table top mount

Содержание MASTERLIGHT HL/LED

Страница 1: ...Gebrauchsanweisung 2 User s Manual 12 Mode d emploi 22 Istruzioni per l uso 32 Instrucciones de empleo 42 Manual de opera o 52 62 QM 1 045T KaWe MASTERLIGHT HL LED...

Страница 2: ...aterial Einhaltung der Richtlinien Zertifikate China UkrTEST Ukraine US GOST R Russia Gebrauchsanweisung Praxisleuchte KaWe MASTERLIGHT HL LED Sehr geehrter Kunde vielen Dank dass Sie sich f r ein KaW...

Страница 3: ...ohre ohne Bremsrollen einh ngen 4 Sechskantschraube eindrehen 5 Sechskantschraube anziehen 6 Praxisleuchte Oberteil auf Fu teil schieben Bremsrollen arretieren Zur Fortbewegung Bremsrollen l sen 3 2 M...

Страница 4: ...ECHNISCHE DATEN Maximale H he ca 211 cm Oberteil Schwenkbereich ca 82 cm Durchmesser Standfu ca 70 cm Gewicht ca 4 7 kg Netzspannung 100 240Volt Halogen 12V 35W 5 A max Lebensdauer der Halogen Lampe 1...

Страница 5: ...L LED verwendet HF Energie ausschlie lich zu seiner internen Funktion Daher ist seine HF Aussendung sehr gering und es ist unwahrscheinlich das benachbarte elektronische Ger te gest rt werden HF Ausse...

Страница 6: ...GHT HL LED benutzt wird die obigen bereinstimmungspegel berschreitet sollte KaWe MASTER LIGHT HL LED beobachtet werden um die bestimmungsgem e Funktion nachzuweisen Wenn ungew hnliche Leistungsmerkmal...

Страница 7: ...s China UkrTEST Ukraine USA GOST R Russia Dear Customer thank you for choosing a KaWe product Our products are known for their high quality and longevity Pleasereadtheseinstructionsthoroughlyandcarefu...

Страница 8: ...5 Tighten the hexagon head screw 6 Push the upper part of the examination lamp onto the floor stand post Lock the brake rollers Loosen the brake rollers to move the examination lamp Mounting parts 1...

Страница 9: ...taining acids 5 TECHNICAL DATA Max height approx 211 cm Lamp arm pivoting range approx 82 cm Diameter of floor stand base approx 70 cm Weight approx 4 4 kg Supply voltage 100 240Volt Halogen 12V 35W 5...

Страница 10: ...ccording to IEC 61000 4 11 5 UT 95 dip in the UT for a period 40 UT 60 dip in the UT for 5 periods 70 UT 30 dip in the UT for 25 periods 5 UT 95 dip in the UT for 5 seconds 5 UT 95 dip in the UT for a...

Страница 11: ...e conducted If the measured field strength at the location at which the KaWe MASTERLIGHT HL LED is used exceeds the applicable compliance level stated above the equipment should be checked at each of...

Страница 12: ...tique Utiliser le dispositif seulement dans des locaux secs 10 Mat riau co compatible Respect des directives certificats suivantes Chine UkrTEST Ukraine USA GOST R Russie Cher client nous sommes tr s...

Страница 13: ...six pans 6 Mettre la partie sup rieure de la lampe d examen sur la partie inf rieure Bloquer les roulettes frein D bloquer les roulettes frein pour le d placement Pi ces de montage 1 Mettre la partie...

Страница 14: ...maximale 211 cm env Plage de pivotement de la partie sup rieure 82 cm env Diam tre du pi tement 70 cm env Poids 4 7 kg env Tension de r seau 100 240V Halog ne 12V 35W 5 A max Dur e de vie de l ampoul...

Страница 15: ...de 95 de UT pour un demi cycle 40 UT creux de 60 de UT pour 5 cycles 70 UT creux de 30 de UT pour 25 cycles 5 UT creux de 95 de UT pour 5 secondes La qualit du secteur lectrique doit tre identique ce...

Страница 16: ...utiliser le dispositif dans cet environnement Tests d immunit Niveau IEC 60601 Niveau de conformit Environnement lectromagn tique Lignes de conduite Perturbations conduites induites par les champs ra...

Страница 17: ...deve essere utilizzato in luogo asciutto Avvertenza campo elettromagnetico Utilizzo in ambiente asciutto 10 Materiale ecocompatibile Osservanza delle direttive certificati Cina UkrTEST Ucraina US GOS...

Страница 18: ...ale 5 Stringere la vite a testa esagonale 6 Spingere la parte superiore della lampada sulla base Bloccare le ruote con freno Sbloccare le ruote per gli spostamenti Parti da montare 1 Spingere la parte...

Страница 19: ...parte superiore ca 82 cm Diametro piede di appoggio ca 70 cm Peso ca 4 7 kg Tensione di rete 100 240Volt Alogena 12V 35W 5 A max Durata di vita della lampadina alogena 1 000 h LED 12V 6 5W 0 8 A max...

Страница 20: ...i UT 5 UT per 5 secondi 95 calo di UT 5 UT per ciclo 95 calo di UT 40 UT per 5 cicli 60 calo di UT 70 UT per 25 cicli 30 calo di UT 5 UT per 5 secondi 95 calo di UT La qualit della tensione di aliment...

Страница 21: ...a lampada KaWe MASTERLIGHTHL LED superasse i livelli di concordan za sopraddetti la KaWe HL LED dovrebbe essere tenuta in osservazione per garantire un funzionamento secondo le norme Osservando caratt...

Страница 22: ...ente en locales secos 10 Material ecocompatible Cumplimiento de las directivas los certificados China UkrTEST Ucrania USA GOST R Rusia Estimado cliente le agradecemos la confianza que ha depositado en...

Страница 23: ...nillo de cabeza hexagonal 6 Deslizar la parte superior de la l mpara de exploraci n sobre la parte inferior Frenar las ruedas Quitar el freno de las ruedas para mover el soporte Piezas 1 Deslizar la p...

Страница 24: ...ro de la parte superior 82 cm aprox Di metro del conjunto de los pies de apoyo 70 cm aprox Peso aprox 4 7 kg Tensi n de alimentaci n 100 240V Hal geno 12V 35W 5 A max Vida til de la bombilla hal gena...

Страница 25: ...s 5 UT 95 de hueco de UT durante medio ciclo 40 UT 60 de hueco de UT durante 5 ciclos 70 UT 30 de hueco de UT durante 25 ciclos 5 UT 95 de hueco de UT durante 5 segundos La calidad de la red de energ...

Страница 26: ...rarse de que se emplea en dicho entorno Pruebas de inmunidad Nivel de prueba IEC 60601 Nivel de cumplimiento Entorno electromagn tico Gu a RF conducida seg n IEC 61000 4 6 RF radiada seg n IEC 61000 4...

Страница 27: ...Aplicar o aparelho somente em locais secos 10 Material ecol gico Observ ncia das diretivas certificados China UkrTEST Ukraine EUA GOST R R ssia Estimadosclientes agradecemosporteremselecionadoumprodu...

Страница 28: ...so de sextavado 5 Apertar o parafuso de sextavado 6 Encaixar a parte superior do foco de exame sobre a base da estrutura Travar os rod zios com trav o Para fazer avan ar destravar os rod zios com trav...

Страница 29: ...aprox 82 cm Di metro da base da estrutura aprox 70 cm Peso aprox 4 7 kg Tens o de alimenta o 100 240Volt Halog neo 12V 35W no m x 5 A Vida til da ampola hal gena 1 000 h LED 12V 6 5W 0 8 A max Vida t...

Страница 30: ...quebra de UT para 25 ciclos 5 UT 95 quebra de UT durante 5 segundos A qualidade da corrente el trica deve ser equivalente de um ambiente hospitalar ou comercial t pico Se o utilizador do foco KaWe MA...

Страница 31: ...tiliza o do foco KaWe MASTERLIGHT HL LED ultrapassar o n vel de conformidade de RF indicado acima o foco KaWe MASTERLIGHT HL LED dever ser observado para verificar o respetivo funcionamento normal Cas...

Страница 32: ...12 5 0A KaWe MASTERLIGHT LED 100 240 47 63 0 7 0 35A 12 2 08A 3 1 2 3 1 1 1 8 1 1 KaWe 5 IEC VDE 0100 710 LOT T EC II 10 KaWe LED 50 000 1 MPG I KaWe MASTERLIGHT LED O 1 62 2 KaWe MASTERLIGHT LED 63 3...

Страница 33: ...64 65 1 2 3 4 5 6 1 2 3 1 5 3 2...

Страница 34: ...4 1 20 4 2 20 4 3 1 2 3 4 5 211 82 5 70 4 7 100 240 12 35 5 1 000 LED 12 6 5 0 8 LED 50 000h LED 8 24 HL 3200 LED 4000 HL 30 44 000Lux LED 30 31 000Lux 10 C 40 C 30 75 700 1060 10 C 50 C 0 5 100 6 Ka...

Страница 35: ...1000 4 5 1 2 1 2 IEC 61000 4 11 5 UT 95 UT 0 5 40 UT 60 UT 5 70 UT 30 UT 25 5 UT 95 UT 5 5 UT 95 UT 0 5 40 UT 60 UT 5 70 UT 30 UT 25 5 UT 95 UT 5 KaWe MASTERLIGHT LED 50 60 IEC 61000 4 8 3 A 30 A UT 7...

Страница 36: ...0 12 0 23 0 1 0 38 0 38 0 73 1 1 20 1 20 2 30 10 3 80 3 80 7 30 100 12 00 12 00 23 00 d P 1 80 800 2 11 2 a KaWe MASTERLIGHT LED KaWe MASTERLIGHT LED IEC 60601 IEC 61000 4 6 IEC 61000 4 3 3 B 150 80...

Страница 37: ...ik weltweit Alle Angaben ohne Gew hr nderungen vorbehalten All information is without guarantee and subject to change Informations sous toutes r serves Sous r serve de modfications Tutte le informazio...

Отзывы: