21
Optional Tank Low Switch
Installing the tank low float switch about 2/3rds down from the top of your water tank allows the
Spectra Connect to run in Auto Fill mode; automatically filling your water tank, stopping itself,
fresh water flushing, returning to Auto Store mode, and then turning itself on again to fill the tank
when the water level drops below the Tank Low Switch with no additional user commands.
Drill
5/8”
hole into the side of the fresh water tank that is being filled by the watermaker. This can
be installed wherever there in convenient access to the tank, approximately 2/3rds of the way
down from the top of the tank.
Drill
5/8”
hole
Tank Switch Installation
2/3
The float switch must be connected to the Tank Switch 2 terminals on the Spectra Connect
control board at the Feed Pump Module
.
There is no polarity.
For Instructions on enabling the
‘
Auto Fill
’
mode see the System Settings instructions
later
in this manual.
Watermakers should never be run unattended!
Tank Switch 2