Spectra Watermakers Commissioning Report –
Page 1
(To be completed by authorized installer)
Fill out the below checks as completely as possible. Check any boxes that apply and note any concerns.
PURGE
□
Storage Chemicals have been purged with PRV open
Length of purge: _______Minutes
□
Diversion Valve is up, in reject position
□
Filter condition has been calibrated
□ “
Run Manual
”
switch engages full speed
□ “
Service
”
switch engages flush speed
RUN HIGH MODE CHECKS
Product Flow: _____________ GPH/LPH
Confirmed Product Flow Rate ___________GPH/LPH
□
Technician Flow meter. Brand________________
□
Hand Measurement _______Gal/Liters in _____SEC/MIN
Product Quality: __________ PPM
□
Confirmed product quality with handheld TDS meter
Feed Pressure: __________ PSI/BAR
Boost Pressure (with clean prefilters): ________PSI/BAR
Brine Flow Rate: _______________ GPM/LPM
Measurement taken with:
□
Technician Flow meter. Brand_________________
□
Hand Measurement: _______Gal/Liters in _____SEC/MIN
□
Boost Pump runs
□
Output and motor speed decrease when low mode is engaged
Notes:__________________________________________________________
______________________________________________________________________
FRESHWATER FLUSH
□
Freshwater Flush solenoid valve opens
□
Feed Pump is not cavitating when system flushes with seacock closed
When seacock is open, what is the ppm of brine discharge at the end of the flush_______
Flush duration is ________Minutes
□
Needed to change flush time
□
Needed to change speed of feed pump during flush
Notes:__________________________________________________________
______________________________________________________________________
*If the system does not have a dedicated forward
-
facing scoop type thru
-
hull or will be on a vessel that
moves faster than 15 knots the system needs to complete the following sea trial checks. Spectra
Watermakers reserves the right to require a sea trial from any customer before approving a
commissioning report.
SEA TRIAL
□
Watermaker will flush while underway
□
Watermaker will start while underway
While the vessel is underway moving _______KNOTS/MPH/KPH the watermaker is producing
_______ GPH/LPH at ______PPM
The following checklist is designed to confirm that the watermaker installation meets Spectra
standards and that the system is performing at specification.
C
U
T
H
ER
E
Содержание Spectra Catalina 340C
Страница 2: ...2...
Страница 15: ...15 John Guest Super Speedfit Fittings...
Страница 50: ...50 This page intentionally left blank...
Страница 64: ...64 Wiring Schematic...
Страница 71: ...71 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB10 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used...
Страница 73: ...73 Parts 1...
Страница 74: ...74 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Страница 78: ...78...
Страница 80: ...80...
Страница 83: ...83...