TECHNICAL DESCRIPTION
ULTRAFLOW
®
54 DN150-250
5512-876 GB/04-2012/Rev. F1
36
Galvanically separated output module (Y=3). ULTRAFLOW
®
is powered by the built-in supply (Z=2, 7 or 8).
Cable length to ULTRAFLOW
®
depends on calculator.
To calculator:
Type:
Open collector.
Connection:
Three-wire via the built-in 39.2 k
Ω
pull-up.
Module Y=3
OC and OD
Max input voltage
6 V
Max input current
0,1 mA
ON condition
U
≤
0,3 V @ 0,1 mA
OFF condition
R
≥
6 M
Ω
Table 14
Concerning pulse figures and pulse durations, see
paragraph 4.2.3
Diagram 13. Block diagram of galvanically separated output module (Y=3) in ULTRAFLOW
®
54.
Figure 19. Galvanically separated output module (Y=3). Note the omitted
components in the encircled area compared to output module (Y=2).