TECHNICAL DESCRIPTION
ULTRAFLOW
®
54 DN150-250
5512-876 GB/04-2012/Rev. F1
35
8.8.2
Galvanically separated
Galvanically separated output module (Y=2). ULTRAFLOW
®
is powered by the built-in supply module (Z=7 or 8).
Cable length to ULTRAFLOW
®
depends on calculator.
To calculator:
Type:
Open collector.
Connection:
Can be connected as two-wire or as three-wire via the built-in 56.2 k
Ω
pull-up.
Module Y=2
OC and OD
(OB) Kam
Max input voltage
6 V
30 V
Max input current
0,1 mA
12 mA
ON condition
U
≤
0,3 V @ 0,1 mA
U
CE
≤
2,5 V @ 12 mA
OFF condition
R
≥
6 M
Ω
R
≥
6 M
Ω
Table 13
Concerning pulse figures and pulse durations, see
paragraph 4.2.3
Diagram 12. Block diagram of galvanically separated output module (Y=2) in ULTRAFLOW
®
54.
Figure 18. Galvanically separated output module (Y=2).
Содержание ULTRAFLOW 54 DN150-250