6.8 Retrofitting the Sound Enclosure (accessory)
The sound enclosure is supplied already assembled.
➤ The enclosure must be dismantled for fitting to the machine.
6.8.1 Dismantling the sound enclosure
Note how the parts fit together.
➤ Open the snap fastener and unscrew the enclosure from the base plate.
6.8.2 Vent the machine (depressurize)
The machine must be isolated from the air system and completely vented before undertaking
any work on the pressure system.
Precondition The power supply disconnecting device is switched off.
The disconnecting device is locked in the off position.
A check has been made that no voltage is present.
The machine is completely depressurised (pressure gauge reads 0 bar).
The machine has cooled down.
The user's shut-off valve between the machine and the air network is closed.
Fig. 18 Removing the air filter
1
Compressor block
2
Hexagonal nut
3
Machine mounting pad
4
Bracket
5
Air filter
6
Hexagonal nut
DANGER
Dangerous voltage!
There is danger of fatal injury caused by contact with live components.
➤ Switch off and lock out the power supply disconnecting device and check that no voltage is
present.
1. Remove the cable from the motor terminal box.
6
Installation
6.8
Retrofitting the Sound Enclosure (accessory)
No.: 9_5753_04 E
Assembly and operating manual 2-stage piston compressor
EPC-2-G
39
Содержание EPC-2-G Series
Страница 2: ...Original instructions KKW PEPC 1 04 en SBA KOLBEN AGGREGAT 2 STUFIG ...
Страница 6: ...Contents iv Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753_04 E ...
Страница 10: ...List of Tables viii Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753_04 E ...